Table 11
POST error messages
Error code
004h
00Ah
00Eh
00Fh
010h
012h
048h
04Ch
05Dh
05Eh
110h
500h
Error message
CMOS Settings Wrong
KBC BAT Test failed
A: Drive Error
B: Drive Error
Floppy Controller Failure
CMOS Date/Time Not Set
Password check failed
Keyboard/Interface Error
S.M.A.R.T. Status BAD, Backup and
Replace
Password check failed
Un-correctable DRAM ECC Error
detected at cpuXX/DIMM0X
(cpu01/DIMM08)
Unsupported Processor
Description/corrective action
CMOS settings are invalid. This
error can be resolved by using
F9 to load optimal default in the
Setup Utility.
Bat test on keyboard controller
failed
The A: drive could not be
properly initialized by the BIOS.
This message is typically
displayed when the BIOS is
trying to detect and configure
floppy devices in POST
The B: drive could not be
properly initialized by the BIOS.
This message is typically
displayed when the BIOS is
trying to detect and configure
floppy devices in POST
The floppy controller initialized
failed, the devices could not use
normally
The CMOS date and/or time are
invalid. This error can be resolved
by readjusting the system time in the
Setup Utility.
Password is incorrect after retried a
few times. Users might need to reset
the password.
Keyboard controller failed test. This
may indicate a problem with system
hardware.
Hard Disk S.M.A.R.T feature test fail
,indicate a problem with hard disk
If user input incorrect password
more than three times, then display
this error information and continue
to boot.
Detect multi-bit error in the DIMM
prompt, press F1 continue to boot
When install the processor which
isn't in PTM, this will appear.
Diagnostic tools and setup utilities 74