Field Wiring Diagrams for Hydronic Coil with Series 7 Air Handlers
Notes:
1. For Family 7 air handlers, a relay and Heat Pump thermostat are required for cooling only application. For Heat Pump OD applications the relay is not required.
2. For Heat Pump systems, the hydronic coil is designed for Supplemental Heat. It is not designed for Emergency Heat.
Single Stage Cooling
Field wiring
Comfort Control *
W
G
Y1
O
R
B
Y2
Notes:
* Heat Pump thermostat is required. Must be set in Heat Pump configuration.
1. It is recommend to use the enhanced mode blower delay profile. See the
Installer's Guide for S2-3 and S2-4 settings.
2. Wiring must be made as shown for proper operation.
Single Stage Heat Pump
Comfort Control
X2
W
G
Y1
O
R
B
Y2
Field wiring
Notes:
1. Emergency heat mode only delivers 50% airflow.
2. Hydronic heat is designed for supplemental heat during
compressor operation.
3. It is recommend to use the enhanced mode blower delay
profile. See the Installer's Guide for S2-3 and S2-4 settings.
4. Wiring must be made as shown for proper operation.
Page 1
INSTALLER'S GUIDE ADDENDUM Field Wiring Diagrams for Hydronic Coil with Series 7 Air Handlers Notes: 1. For Family 7 air handlers, a relay and Heat Pump thermostat are required for cooling only application. For Heat Pump OD applications the relay is not required. 2.
Page 2
INSTALLER'S GUIDE ADDENDUM Air Conditioner Two Stage Cooling Neatly bundle all low voltage wires behind the service valve cover as shown. Series 7 Air Handler Comfort Control * Yellow /Red Blue Brown Yellow/Black Green Brown Hydronic Typical Boiler Yellow (In) Control Wiring Orange...