inlet flange end.
(2) Remove the inlet pressurizer tank parts.
Refer to picture 16

1.7 Disassemble the water pipe weldment

(1) Loosen the M8X10 bolt which fixes the water pipe weldment on the crankcase cover
(2) Loosen the hoop which connects the thermostat connection pipe and water outlet pipe.
(3) Remove the water outlet pipe weldment.
Refer to picture 17
1.8 Disassemble the thermostat parts, water outlet pipe seat and water outlet connection pipe.
(1) Loosen the two M6X40 bolts which fix the thermostat parts.
(2) Loosen the two M6X20 bolts which fix the water outlet pipe seat.
(3) Remove the thermostat parts, water outlet pipe seat and water outlet connection pipe.
Refer to picture 18
picture 16
picture 17
picture 18