Continuous Pilot / Intermittent Pilot (Cpi / Ipi) Selection; Child Proof Function / Key Lock; Low Battery / Manual Bypass; Split Flow - Napoleon HD81NT-1 Installation And Operating Instructions Manual

Natural gas, propane
Table of Contents

Advertisement

8.7

CONTINUOUS PILOT / INTERMITTENT PILOT (CPI / IPI) SELECTION

A.
Use the Mode Key to guide you to the CPI mode icon.
Transmitter in the OFF position.
B.
Press the UP/DOWN to switch between IPI and CPI
modes. A single BEEP will confi rm reception of the
command.
NOTE: If the system is equipped with a CPI/IPI toggle
switch, set the CPI/IPI to CPI position to enable remote CPI
operation. If the switch is set to IPI then it will only work in
IPI regardless of what is set on the remote control handset.
8.8

CHILD PROOF FUNCTION / KEY LOCK

This function will lock the keys to avoid unsupervised operation.
A.
Press the MODE and UP keys at the same time.
B.
To de-activate this function, press the MODE and UP keys at the same
time.
8.9

LOW BATTERY / MANUAL BYPASS

The life span of the remote batteries depends on various factors: quality of the
batteries, the number of ignitions, the number of changes to the room thermostat set
point, etc.
When the transmitter batteries are low, a Battery Icon will appear on the LCD
display before all battery power is lost. When the batteries are replaced this icon will
disappear.
Not applicable when plugged into 110V.
When the batteries are low, no "beep" will be emitted from the receiver when it receives an ON/OFF command.
This in an alert for the receiver that there's low battery. When the batteries are replaced the "beep" will be
emitted from the receiver when the ON/OFF key is pressed.
If the batteries in the battery holder or transmitter are low, the appliance can be turned on manually by sliding
the three position slider switch on the battery holder to the "ON" position. This will bypass the remote control
feature and the appliance main burner will come on. Likewise, if you want to manually turn the appliance off,
slide the switch to the 'OFF' position.
8.10

SPLIT FLOW

The split fl ow function controls the ability to turn ON/
OFF a second burner.
Use the mode key to guide you to the split fl ow
A.
function.
Pressing the up arrow key will activate the
B.
second burner.
Pressing the down arrow key will deactivate the
C.
second burner. A single "beep" will confi rm the reception of the command.
NOTE: There is no way to modulate the fl ame heights separately.
76
°F
IPI
35.22
35.10A
35.23
76
°F
OFF
35.17A
39
76
°F
CPI
76
°F
76
°F
76
°F
ON
W415-2201 / C / 07.04.19
EN

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hd81pt-1