Fl Ame Height; Blower Speed; Night Light Dimmer Control; Continuous Pilot / Intermittent Pilot (Cpi / Ipi) Selection - Napoleon Ascent Linear Series Owner's Manual

Hide thumbs Also See for Ascent Linear Series:
Table of Contents

Advertisement

Available languages

Available languages

3.4
fl ame height
The remote control has six (6) fl ame levels. With the system on and the fl ame level at the maximum, press the
down arrow key once and it will reduce the fl ame height by one step until the fl ame is turned off.
The up arrow key will increase the fl ame height each time it is pressed. If the up arrow key is pressed while
the system is on but the fl ame is off, the fl ame will come on at the high position. A single "beep" will confi rm
reception of the command.
OFF
3.5

blower speed

If the appliance is equipped with a hot air circulating fan, the speed of
the fan can be controlled by the remote system. The fan speed can be
adjusted through six (6) speeds.
A. Use the mode key to guide you to the fan control icon.
B. Use the up/down arrow keys to turn on/off or adjust the fan
speed. A single "beep" will confi rm reception of the command.
note:
When the desired blower speed is selected, the blower will automatically come on 5 minutes after the main
burner has been turned on and remain on twelve minutes after it has been turned off.
3.6

night light dimmer control

ADD TITLE: Night Light Dimmer Control
The auxiliary function controls the Night Light™ with dimmable control.
A. Use the mode key to guide you to the Night Light™ icon.
B. The intensity of the output can be adjusted through 6 levels.
Use the up/down arrow keys to adjust the output level. A single beep
will confi rm reception of the command.
3.7

continuous pilot / intermittent pilot (CPI / IPI) selection

A. When the transmitter is in the off position, use the mode key to guide
you to the CPI mode icon.
B. Press the up/down to switch between IPI and CPI modes. A single
beep will confi rm reception of the command.
note:
note:
If the appliance is equipped with a CPI/IPI toggle switch, set the CPI/IPI
If the appliance is equipped with an ACS switch, set the switch to CPI
to CPI position to enable remote CPI operation. If the switch is set to IPI
position to enable remote CPI operation. If the switch is set to IPI then it will
then it will only work in IPI regardless of what is set on the remote control
only work in IPI regardless of what is set on the remote control handset.
handset.
3.8

in the event of a power failure

ADD TITLE: IN THE EVENT OF A POWER FAILURE
If the receiver is equipped with batteries they will enable fl ame height control or on/off function to control the
appliance during a power failure. Blower and Night Light™ operation is not possible. Refer to "appliance
operation" section when communications between receiver and transmitter have been lost. The receiver will
emit a "beep" sound to confi rm programming has been successful once power is restored. During a power
failure, if the appliance was on, the fl ame height will stay at the setting prior to the failure. If off when the failure
occurs and then turned on, the fl ame height will come on at "Hi". The fl ame height can then be controlled by the
remote.
76
76
°F
Flame Off
Flame at level 1
remote control layout
76
°F
°F
Flame at level 5
Flame at "Hi" level 6
68
OFF
76
°F
Hi
76
76
°F
Hi
76
76
°F
76
76
°F
IPI
CPI
W415-2759 / B / 10.21.20
EN
°F
°F
°F