Quick Start Guide

C-300 Series Gigabit Managed Switch
1. Unpack the Switch and Check Contents
Rack Mounting Kit—two brackets and eight screws
Four adhesive foot pads
Power Cord—either Japan, US, Continental Europe
or UK
Documentation—Quick Start Guide (this document),
Warranty Card and Safety and Regulatory
Information
Note: The C-300 series switches are for indoor use
only.
Note: For Safety and Regulatory information, refer to
the Safety and Regulatory Information document
included with the switch.
Note: Other documentation, including the Installation
Guide, Web Management Guide, and CLI Reference
Guide, can be obtained from www.signamax.com.

2. Mount the Switch

1
Attach the brackets to the switch.
Use the screws and cage nuts supplied with the rack to
2
secure the switch in the rack.
www.signamax.com
SC30010
SC30020
SC30030
SC30040
SC30050
SC30060
1
2
Caution: Installing the switch in a rack requires two
people. One person should position the switch in the
rack, while the other secures it using the rack screws.
Note: The switch can also be installed on a desktop or
shelf using the included adhesive rubber foot pads.
3. Ground the Switch
1
2
Ensure the rack on which the switch is to be mounted is
1
properly grounded and in compliance with ETSI ETS 300
253. Verify that there is a good electrical connection to
the grounding point on the rack (no paint or isolating
surface treatment).
Attach a lug (not provided) to a #12 AWG (PoE switch) or
2
#18 AWG (non-PoE switch) minimum grounding wire
(not provided), and connect it to the grounding point on
the switch rear panel. Then connect the other end of the
wire to rack ground.
Caution: The earth connection must not be removed
unless all supply connections have been
disconnected.
Caution: The device must be installed in a restricted-
access location. It should have a separate protective
earthing terminal on the chassis that must be
permanently connected to earth to adequately ground
the chassis and protect the operator from electrical
hazards.
– 1 –
E102017-AP-R01
150200001850A

Advertisement

loading

Summary of Contents for SignaMax C-300 Series

  • Page 1: Quick Start Guide

    Information Caution: The earth connection must not be removed unless all supply connections have been Note: The C-300 series switches are for indoor use disconnected. only. Caution: The device must be installed in a restricted- Note: For Safety and Regulatory information, refer to access location.
  • Page 2: Connect Power

    Press the Mode button to change from Ethernet to PoE status: On/Blinking Green — Port has a valid link. ◆ Blinking indicates network activity. On Amber — Port is supplying PoE power. ◆ www.signamax.com – 2 –...
  • Page 3: Hardware Specifications

    Operating: 0°C to 45°C (32°F to 113°F), for SC30020 only Operating: 0°C to 40°C (32°F to 104°F), for SC30050, and SC30020 with one AP50020 only Storage: -40°C to 70°C (-40°F to 158°F) Humidity Operating: 10% to 90% (non-condensing) www.signamax.com – 3 –...