[Source:]Current:transient:alevel; [Source:]Current:transient:blevel - ITech IT8300 Series Programming Manual

Energy-regenerative dc electronic load
Hide thumbs Also See for IT8300 Series:
Table of Contents

Advertisement

Query Syntax
[SOURce:]CURRent:TRANsient:MODE?
Returned Parameters
<CRD>
Related Commands
CURR:TRAN:ALEV

[SOURce:]CURRent:TRANsient:ALEVel

[SOURce:]CURRent:TRANsient:BLEVel

This command specifies the transient level of the input current. The transient
function switches between the level a and level b.
Command Syntax
[SOURce:]CURRent:TRANsient:ALEVel <NRf+>
[SOURce:]CURRent:TRANsient:BLEVel <NRf+>
Parameters
0 through MAX|MINimum|MAXimum|DEFault
Unit
A (amperes)
*RST Value
ALEVEL MAXimum , BLEVel MINnum
Examples
CURR:TRAN:ALEV 5
Query Syntax
[SOURce:]CURRent:TRANsient:ALEVel? [MINimum|MAXimum|DEFault]
[SOURce:]CURRent:TRANsient:BLEVel? [MINimum|MAXimum|DEFault]
Returned Parameters
<NR3>
Related Commands
CURR
TRAN
CURR:TRAN:BLEV 0.5
Copyright © ITECH Electronics Co., Ltd.