Specifications

Network
Protocol
TCP/IP, ARP, ICMP, HTTP, FTP
(server/client), SMTP (client),
DHCP (client), DNS (client), NTP
(client), SNMP (MIB-2)
Compression
Video compression format
JPEG
Image size
NTSC: 704 × 480, 640 × 480, 320 ×
240, 160 × 120
PAL: 704 × 544, 640 × 480, 320 × 240,
160 × 120
Maximum frame rate
JPEG: 30 fps
1) This value indicates the maximum
number of frames that can be
transmitted. The number of frames
actually transmitted may vary
depending on network environments
and camera settings (image size and
image quality settings).
Web browser
Internet Explorer Ver. 5.5 or 6.0
(Available OS: Windows 2000/ XP)
Computer environments
CPU: Pentium III, 1 GHz or higher
(Pentium 4, 2 GHz or higher
recommended)
RAM: 256 MB or more
Display size: 1024
Maximum user access
JPEG mode: 10 users
Network security
Password (basic authentication), IP
filtering
Other functions
Image trimming, built-in clock, etc.
Camera
Image device
1/2.7 type interline transfer CCD,
1,300,000 picture elements
Effective picture elements
1280 (horizontal) × 960 (vertical)
(Ring-shaped)
Lens mount
C mount
Signal format
NTSC/PAL
VBS: within 1.0 Vp-p ± 5 %,
75 ohms, sync negative
Scanning
NTSC
525 lines, 2:1 interlace
PAL
625 lines, 2:1 interlace
Synchronization
INT only
32
Specifications
1)
(VGA)
768
×
Horizontal resolution
480 TV lines (analog video)
Signal-to-noise ratio
50 dB (AGC OFF, Weight On) (analog
video)
Minimum illumination
0.3 lux
AGC
Switchable automatically
Exposure control
AUTO iris
Electronic shutter
CCD Iris
White balance ATW
BLC
Switchable automatically
Interface
Network port
10BASE-T/100BASE-TX (RJ-45)
(extended from the multi cable)
Video output
BNC connector (extended from the
multi cable)
1.0 Vp-p, 75 ohms, unbalanced,
sync negative
Others
Power supply
12 V DC ± 2 V
24 V DC ± 2 V
Power consumption
10 W max.
Operating temperature
-20 °C to +50 °C [-4 °F to +122 °F] for
continuous operation
-5 °C to +50 °C [23 °F to 122 °F] for
starting the unit
2) When the operating temperature is
around -20 °C, the camera image may be
noisy.
3) If you turn on the power of the unit at
temperatures lower than -5 °C (23 °F),
the unit may not start. In this case, warm
the unit and turn it on again. Be sure to
wait for several seconds between
turning off and turning on the unit.
Storage temperature
20 °C to +60 °C
(
4 °F to +140 °F)
Operating humidity
20 to 80 %
Storage humidity
20 to 95 %
Dimensions
135 × 164.5 × 166.1 mm
3
1
(5
/
× 6
8
Mass
Approx. 2.0 kg (4 lb 7 oz)
Supplied accessories
CD-ROM (Setup program and User's
Guide) (1)
Wire rope (1)
2)
3)
5
/
× 6
/
inches)
2
8