For customers in other countries POWER REQUIREMENTS WARNING The SNC-DP10 operates on 24 V DC or 12 V DC. The SNC-DP10 automatically detects the power. This is a Class A product. In a domestic environment, this product may cause radio interference in which case CAUTION for U.S.A.
Table of Contents Overview Features ..................6 How to Use This User’s Guide ........... 6 Precautions .................. 7 Operating Precautions ................7 Operating the Camera Logging in to Homepage — Welcome Page ......8 Logging in as a User ................8 Logging in as Administrator ..............8 About Viewers ...................9 Configuration of Main Viewer ...........
Page 5
Assigning an IP address using the Setup Program ......26 Changing the Communication Bandwidth........28 Setting the Date and Time ............... 28 Rebooting the SNC-DP10..............29 Assigning the IP Address to the Camera Using ARP Com- mands................... 29 Using the SNMP ................. 30 1.
Overview How to Use This User’s Guide This User’s Guide explains how to operate the SNC- Features DP10 Network Camera from a computer. The User’s Guide is written to be read on the computer This is dome-shaped color video camera for which the 1/ display.
• Use a blower to remove dust from the lens. This Sony product has been designed with safety in • Clean the body with a dry soft cloth. If it is very dirty, mind.
Select Tool from the menu bar of Internet Explorer, Operating the Camera then select Internet Options and Security tab in sequence. The Operating the Camera section explains how to monitor the image from the camera using your Web Click the Internet icon (when using this unit via browser.
Enter the user name and password for Java (Sun) is not displayed, it means that Java is not Administrator, then click OK. installed. You need to install Java. The user name “admin” and the password “admin” Java Plug-in Ver. 1.5.0_04, Ver. 1.5.0_05 are set at the factory for the Administrator.
Configuration of Main Frame rate Click the down-arrow button in the Frame rate box and Viewer select the frame rate with which the images are transmitted, from the drop-down list. When you select the viewer, the main viewer is You can select the frame rate from among the following: displayed.
Monitor image Capturing a Monitor The image shot by the camera is shown here. Regarding the camera image, DualHalfWide mode or Ring mode Image can be selected in Camera mode (page 17) of Camera setting. If you click the Capture button on the main viewer, The date and time is displayed at the top of the window.
Camera Administrating the Camera Displays the Camera setting page. See “Setting the Camera — Camera setting Page” on page 16. The Administrating the Camera section explains how to set the functions of the camera by the Administrator. Network For the monitoring of the camera image, see “Operating Displays the Network setting page.
Use this page to perform the principal settings of the This is not a problem. software. System setting Section Video in setting Only SONY RPU-C251/352 can be selected in this camera. Title bar name Type a name to display on the title bar up to 32 characters.
Default frame rate Notes Select the initial frame rate which is selected when you • Before using the Exclusive control mode, you need to log in this unit and display the main viewer. set the date and time correctly on this unit and the Click the down-arrow button in the box and select the connected computer.
Image quality Setting the Camera Select the image quality from Level 1 to Level 10. A higher level gives a higher image quality. According — Camera setting Page to the condition of the communication line, the frame rate may be reduced. When you click Camera on the Administrator menu, the Camera setting page appears.
Page 17
DualHalfWide. This setting is valid when the Camera mode is set to Ring. Model Name You do not normally have to change the default setting. The model name of this model "SNC-DP10" is Up: The trimming circumference increases. displayed. Down: The trimming circumference decreases.
Shutter Temperature Select the shutter speed of the electronic shutter. You can The value of the temperature sensor on the basal plate select one of 16 levels from 1/7.5 to 1/10000. In the inside the camera is displayed. The built-in fan is turned factory, it is set to 1/7.5.
OK/Cancel Camera control mode setting See “Buttons common to every setting page” on page section Mode Select the answer level of when you use the arrow button of the control panel. When you press Step, the answer levels are displayed and you can select one of them. But their use is limited in this camera.
Primary DNS Configuring the Network Type the IP address of the primary DNS server. — Network setting Page Secondary DNS Type the IP address of the secondary DNS server, if When you click Network on the Administrator menu, necessary. the Network setting page appears. Use this page to configure the network to connect this Bandwidth control unit and the computer.
Access right Setting the User Select the access right for each user from the drop-down list. The rights afforded to each access right are as — User setting Page follows: Level 1 - Level 3: Allows monitoring of the camera When you click User on the Administrator menu, the image and capturing the display.
Network address/Subnet 1 to Network Setting the Security address/Subnet 10 Type the IP addresses and subnet mask values you want — Security setting Page to allow or deny access to this unit. You can specify up to 10 IP addresses and subnet mask When you click Security on the Administrator menu, values.
Re-type password Sending Images to FTP To confirm the password, type the same characters as you typed in the Password box. Server Remote path — FTP client setting Page Type the path to the destination up to 64 characters. When you click FTP client on the Administrator menu, the FTP client setting page appears.
Setting the FTP Server Function Downloading Stored — FTP server setting Page Images You can register up to 10 user names and passwords to allow logging in this unit using the FTP client software — FTP server setting Page of the computer. When you click FTP server on the Administrator menu, the FTP server setting page appears.
Recipient e-mail address Sending an Image via E- Type the recipient E-mail address up to 64 characters. You can specify up to three recipient E-mail addresses. mail — SMTP setting Page Administrator e-mail address When you click SMTP on the Administrator menu, the Type the Administrator e-mail address up to 64 SMTP setting page appears.
The “File Download” dialog opens. Others Click Open. Note If you click “Save this program to disk” on the “File Using the Supplied Download” dialog, you will not be able to perform set up correctly. Delete the downloaded file, and Setup Program click the Setup icon again.
Page 27
To obtain the IP address automatically from a Normally, select 80 for the HTTP port No. To use DHCP server: another port number, type the port number between Select Obtain an IP address automatically. 1024 and 65535 in the text box. Type the Administrator name and Administrator password.
Click the Bandwidth control tab to display the bandwidth setting window. The current bandwidth is displayed in Current bandwidth. Click to select the SNC-DP10 you want to set the date and time for. Select the date/time format from the Date time format drop-down list.
Due to the network properties, there may be a slight Address to the Camera difference between the displayed computer's date and time and those set on the SNC-DP10. Using ARP Commands Rebooting the SNC-DP10 This section explains how to assign an IP address to the...
“ID=1”, information using the inqjs=snmp (JavaScript the community name “public”, and enables sending parameter) format. of traps to the host having the IP address “192.168.0.101”. var sysDescr=“SONY Network Camera SNC-DP10” ...1 var sysObjectID=“1.3.6.1.4.1.122.8501” ...2 2. Setting Commands var sysLocation=“”...
Page 31
sysName=<string> <Command> Set the case of “mib-2.system.sysName.0” in the http://ip_adr/snmpdconf/snmpdconf.cgi? <string> position. The maximum length of snmpd=restart <string> is 255 characters. enaAuthTraps=<value> Set the case value of “mib-2.snmp.snmp EnableAuthenTraps.0” in the <string> position. Type “1” (enable) or “2” (disable) in the <value> position.