To remove the control panel:
1. Turn the control knobs to the OFF position and turn off
the gas supply to the unit.
2. Pull the control knobs from the stems and set aside.
3. Remove the drip tray.
4. Using a Phillips screwdriver, unscrew and remove the
control panel fastener screws (located on the left and
right front sides of the control panel). Retain the screws
for later re-installation.
5. Carefully open the control panel by lifting and pulling
the control panel from the frame.
Important: When opening, take caution to not damage any
wiring.
6. Disconnect the two wires from the back of the igniter at
the control panel end. (polarity does not matter when
reconnecting the wires).
Note: Secure any disconnected wires (coming from the
inside of the unit) to prevent them from falling in.
Note: Whenever reconnecting any wires, apply a small
amount of dielectric grease to the male connector,
PCG.rev04282017- 10:53

CONTROL PANEL REMOVAL

Important: During reinstallation; prior to opening the gas
18
then make the connection. This will ensure
conductivity and prevent moisture from affecting the
contact.
shut-off valve, be sure the control knobs are in
the OFF position.