Read all instructions before lighting, and follow these instructions each time you light the unit.
ELECTRONIC LIGHTING
1. Open lid.
2. Turn all gas control knob(s) to their OFF position(s).
3. Turn on the gas at its source and press the master
switch.
Note: DO NOT turn on more than one valve at a time for
either electronic or manual lighting.
Use HI (high)
to light
To Turn OFF
Press knob in to turn
Fig. 1 - Control knob
4. Depress the desired control knob for 5 seconds, then,
while pressing turn it counterclockwise to the HI LIGHT
position. Press and hold the igniter button. Once the
burner lights, release igniter button.
CAUTION:
If a burner does not light within fi ve (5) seconds of turning
on the control knob, depress the knob and turn it to the
OFF position. WAIT FIVE (5) MINUTES before repeating
step 4. If you smell gas, follow the instructions on the cover
of this manual. If the burners still do not light after several
attempts, refer to the instructions for manual lighting.
5. Repeat step 4 for each additional burner to be lit.
WHEN USING A PORTABLE PROPANE TANK
Propane tanks are equipped with a safety shutdown
device that may cause low or no gas pressure/fl ame at
the burners if operating and lighting instructions are not
followed exactly (See important note in the TROUBLE-
SHOOTING section for more details.)
PCG.rev04282017- 10:53
LIGHTING (IGNITION) INSTRUCTIONS
OFF
Position
To Turn ON
MANUAL LIGHTING
CAUTION: Always wait fi ve (5) minutes for gas to clear
after any unsuccessful lighting attempt.
1. Follow steps 1 through 3 (left).
2. Insert either a burning long-barrel butane lighter or a
burning long-stem match through a hole in the control
panel opening to the top of the lighting tube (Fig. 2).
For backburners, hold the fl ame against the surface of
the backburner.
3. Hold the match/lighter fl ame at the top of the
lighting tube for 5 seconds. Then depress the
appropriate control knob and while pressing turn it
counterclockwise to the HI LIGHT position. Remove
the lighter or match when the burner lights, and release
the control knob.
4. If the burner does not light within fi ve (5) seconds of
turning the control knob, immediately depress the
knob and turn the valve to OFF. WAIT FIVE (5)
MINUTES before repeating steps 2 through 4 of the
MANUAL LIGHTING instructions.
Fig. 2 - Manual lighting
SHUTTING OFF THE UNIT
To shut off the unit, depress each valve control knob and
while pressing turn it clockwise to the OFF position.
Always close the valve from the gas supply after each use
of the unit.