SAFE USE & MAINTENANCE OF PROPANE GAS CYLINDERS
READ AND FOLLOW ALL WARNINGS PROVIDED WITH THE PROPANE-GAS CYLINDER.
When operating this appliance with a propane-gas cylinder, these instructions and warnings MUST
be observed. FAILURE TO DO SO MAY RESULT IN A SERIOUS FIRE OR EXPLOSION.
CYLINDER/CONNECTOR REQUIREMENTS
1. Propane-gas cylinders, valves, and hoses must be
maintained in good condition and must be replaced if
there is visible damage to either the cylinder or valve. If
the hose is cut or shows excessive abrasion or wear, it
must be replaced before using the gas appliance (see
3.).
2. This unit, when used with a cylinder, should be
connected to a standard 5-gallon (15 lb.) propane-gas
cylinder equipped with an OPD (Overfill Prevention
Device). The OPD has been required on all cylinders
sold since October 1,1998, to prevent overfilling.
3. Cylinder dimensions should be approximately 12" (30.5
cm) in diameter and 18" (45.7 cm) high. Cylinders must
be constructed and marked in accordance with the
Specifications for Propane Gas Cylinders of the U.S.
Department of Transportation (D.O.T.) or the National
Standard of Canada, CAN/CSA-B339, Cylinders,
Spheres, and Tubes for Transportation of Dangerous
Goods.
4. The cylinder used must include a collar to protect the
cylinder valve, and the cylinder supply system must be
arranged for vapor withdrawal.
5. The pressure regulator and hose assembly (Figure
1) supplied with this outdoor gas appliance (L.P.
models only) must be used. Original and replacement
pressure regulator and hose assemblies must be those
specified by the manufacturer for connection with a
cylinder connecting device identified as Type I by the
ANSI Z 21.58/CGA 1.6 (see PARTS LIST for ordering
information).
6. The propane-gas cylinder valve must be equipped with
a cylinder connection coupling device, described as
Type I in the standard defined in paragraph 5. above.
This device is commonly described as an Acme thread
quick coupler.
7. If the propane-gas cylinder comes with a dust plug,
place the dust cap on the cylinder valve outlet
whenever the cylinder is not in use.
QUICK COUPLER OPERATION
To connect the regulator/hose assembly to the
propane-gas cylinder valve fitting: Press the hand nut
on the regulator over the Acme thread fitting on the cylinder
SECURING THE PROPANE GAS CYLINDER
Insert propane tank into hole in cabinet base (Fig. 1-A).
Raise bracket over lip of propane tank and tighten thumbscrew (Fig 1-B).
Follow instructions above to connect supply.
PCG.rev04282017- 10:53
IMPORTANT FOR YOUR SAFETY
valve. Turn the hand nut clockwise to engage the threads
and tighten until snug. The use of pliers or a wrench should
not be necessary. Only cylinders marked "propane" may be
used.
To disconnect: Turn the hand nut counterclockwise until
detached (Figure 1).
Important: Before using the unit, and after each time the
cylinder is removed and reattached, check the hose for
wear (see 1.) and check all connections for leaks. Turn
off the unit valves and open the main cylinder valve, then
check connections with soapy water. Repair any leaks
before lighting the unit.
CAUTION: Always turn the propane cylinder main valve off
after each use, and before moving the unit and cylinder or
disconnecting the coupling. This valve must remain closed
and the cylinder disconnected while the appliance is not
in use, even though the gas flow is stopped by a safety
feature when the coupler is disconnected.
Carefully inspect the hose assembly each time before
the gas is turned on. A cracked or frayed hose must be
replaced immediately.
If the appliance is stored indoors, the cylinder must be
disconnected and removed. Disconnected cylinders must
be stored outdoors, out of the reach of children, with
threaded valve plugs tightly installed, and must not be
stored in a building, garage, or any other enclosed area.
FOR YOUR SAFETY
a. DO NOT store a spare propane-gas cylinder under or
b. NEVER fill the cylinder beyond 80-percent full.
c. IF THE INFORMATION IN A. AND B. IS NOT
(Figure 1) Type I Acme Quick Coupler
10
near this appliance.
FOLLOWED EXACTLY, A FIRE CAUSING DEATH OR
SERIOUS INJURY MAY OCCUR.
Hand Wheel
QCC
Acme Thread
Type 1
Brass Fitting
Valve
Pressure
Relief
Valve
Liquid Level
Indicator
(optional)
1-A
Regulator
Vent
Acme Thread
Hand Nut
Hose