SIDE AND REAR WALL CLEARANCES
NOTE:
10" from back of hinge required to open lid.
For the minimum clearances between the grill
and any side or rear walls, your setup must fall
within one (or more) of the following:
A. Clearance between grill and strictly non-
combustible wall
(i.e. brick wall, see Figure 1)
• The grill must have a minimum of 4" right, left,
and rear clearance from any non-combustible
wall.
(To allow for proper ventilation and prevent
dangerous overheating.)
B. Clearance between grill and a protected
combustible wall
(i.e. a non-combustible wall in front of a
combustible wall to serve as a barrier. This
can be accomplished by brick, or a metal stud
finished with non-combustible substrate, see
Figure 2)
• The grill must have a minimum of 14" right,
left, and rear clearance from the protected
combustible wall.
(The 4" non-combustible material plus an
additional X" clearance between the grill and
protected wall.)
C. Clearance between grill and combustible
wall
• The grill must have a minimum of 18" right, left,
and rear clearance from any combustible wall
(see Figure 3).
BACKSPLASH CLEARANCE (IF APPLICABLE)
If a non-combustible backsplash exists, it must
have a minimum of a 5" clearance from the
rear of the grill (to allow for hinge clearance,
proper ventilation and to prevent dangerous
overheating). See Fig. 4.
INSTALLATION REQUIREMENTS
Figure 1 Clearance 'A' Diagram
Figure 2 Clearance 'B' Diagram
Figure 3 Clearance 'C' Diagram
Figure 4 Backsplash Clearance Diagram
7
4"
14"
18"
4-1/4" of open space behind grill
23-1/4"
36 1/2"
11"
36 1/2"
27-1/2"
PCG.rev04282017- 10:53