Optical Data; 15.2.1 Reading Performance; 15.2.2 Code Specifications - Leuze electronic DCR 248i Original Operating Instructions

Camera-based code reader
Table of Contents

Advertisement

Tab. 15.4:
Environmental data
Ambient temp. (operation/stor-
age)
Air humidity
Ambient light
Electromagnetic compatibility
Vibration
Continuous shock
Certifications
Conformity
15.2

Optical data

Integrated LED illumination
Integrated feedback LED
Beam exit
Image sensor
Number of pixels
Optics models
Electronic shutter speeds

15.2.1 Reading performance

Reading distance
Object speed

15.2.2 Code specifications

Code type: 1D
Code type: stacked
codes
Code type: 2D
Leuze electronic
0 °C ... +45 °C/-20 °C ... +70 °C
max. 90% rel. humidity, non-condensing
Max. 2000 Lux
EN 61000-6-2, EN 61000-6-4
IEC 60068-2-6, test Fc
IEC 60068-2-29, test Eb
UL 60950-1
CAN/CSA C22.2 No. 60950-1-07
CSA C22.2 No. 60950-1-07
CE, FCC, UL
Red light (visible, 616 nm)
Risk group 0 (exempt group)
Acc. to IEC 60825-1, EN 62471:2008
Green (528 nm)
Front
Global shutter CMOS Imager
1280 x 960 pixels
Resolution
• High Density (N)
0.127 mm (5 mil) ... 0.25 mm (10 mil)
• Medium Density (M)
0.19 mm (7.5 mil) ... 0.33 mm (13 mil)
• Low Density (F)
0.25 mm (10 mil) ... 0.5 mm (20 mil)
68 µs ... 5 ms (flash)
see chapter 6.1.3 "Determining the reading distance"
• N-optics: Up to 4 ms at m=0.19 mm (7.5 mil)
• M-optics: Up to 5 ms at m=0.25 mm (10 mil)
• F-optics: Up to 7 ms at m=0.33 mm (13 mil)
Code 128 EAN 128 (GS1-128), Code 39, Code 2/5 Interleaved, EAN 8/
EAN 13, UPC A/E, Pharmacode, Codabar (Monarch), Code 93
GS1 DataBar (Omnidirectional, Expanded, Limted, Truncated)
GS1 DataBar (Stacked Omnidirectional, StackedExpanded)
PDF417
DataMatrix (ECC200), Aztec Code, GS1 Aztec Code, GS1 DataBar (ECC200)
QR-Code, GS1 QR-Code
DCR 248i
Technical data
97

Advertisement

Table of Contents
loading

Table of Contents