Module 107 - Entry Data 7 - Leuze electronic DCR 248i Original Operating Instructions

Camera-based code reader
Table of Contents

Advertisement

Input data
Error code
Input data length: 1 byte
Tab. 10.27:
Output data structure module 106
Output data
Reserved
New entry
Reserved
Entry data
length
Data
Output data length: 3 bytes consistently + 96 bytes of result information
10.4.19 Module 107 – Entry data 7
PROFINET-IO module identifier
• Module ID: 1107
• Submodule ID: 1
NOTICE
Ä Data reset does not affect the output data toggle bits
Ä If fragmentation is used, the application must set the output data of the entry data fragmen-
tation module for each fragment that is to be transmitted before the toggle bit is toggled in
the entry data module (see chapter 10.4.4 "Module 16 – Fragmented entry").
Description
The module defines the transfer of entry data to a command interpreter (Cmd interpreter) in the device.
Leuze electronic
Address
Data type
0.4-0.7
Bit
Address
Data type
0.0
0.1
0.2
0.3
0.4
0.5
Bit
0.6
Bit
0.7
Bit
1
UN-
SIGNED16
3..98
96x
UN-
SIGNED8
Value range
Default
0: No error
0
1: Receive buffer
overflow
2: Sequence er-
ror
3: Invalid length
entry
4: Invalid frag-
ment length entry
5: Length change
in a sequence
Value range
Default
0
0
0
0
0
0 -> 1: New entry
0
1 -> 0: New entry
0
0
0-65535
0
0-FFh
0
DCR 248i
Unit
Explanation
---
Cause of error for re-
jection of the fragment.
Unit
Explanation
Free
Free
Free
---
Free
---
Free
---
The toggle bit shows
whether new entry data
is present
---
Free
---
Free
---
Data length of the ac-
tual information.
---
Information with a
length of consistently
96 bytes.
PROFINET
79