Profinet Project Modules; 10.4.1 Overview Of The Modules - Leuze electronic DCR 248i Original Operating Instructions

Camera-based code reader
Table of Contents

Advertisement

10.4

PROFINET project modules

NOTICE
Overwriting of data by PLC!
Ä During the configuration phase, the DCR 248i receives data telegrams from the IO controller
(master). Before the data telegrams are evaluated and the respective settings are made, all
interface-specific settings are reset to default values. This ensures that the settings of mod-
ules that are not selected are set to the default values.
NOTICE
Ä You can find the default values of the DCR 248i in the module descriptions.
Ä Examples for using the modules: see chapter 18.5 "Communication examples".
NOTICE
Behavior of the input/output data
Ä The default value of the input data bits after switching on the device corresponds to the
specified initial value (generally ZERO).
Ä The outputs are deactivated during device start-up.
Ä For output data with status IOPS = Bad, the downstream functions are switched to a safe
state. This is the case, for example, if the control is switched to the STOP mode. For exam-
ple, an activated device or an output is then deactivated.
In the event of a connection interruption, the device behaves in the same way.

10.4.1 Overview of the modules

Module
M10
see chapter 10.4.2 "Acti-
vation"
M13
see chapter 10.4.3 "Frag-
mented result"
M16
see chapter 10.4.4 "Frag-
mented entry"
M21
see chapter 10.4.5 "Result
data 1"
M22
see chapter 10.4.6 "Result
data 2"
M23
see chapter 10.4.7 "Result
data 3"
M24
see chapter 10.4.8 "Result
data 4"
M25
see chapter 10.4.9 "Result
data 5"
Leuze electronic
Description
Activation
Control bits for the activation and
transfer of the input data.
Fragmented result
Transmission of the results in the
fragmented mode
Fragmented entry
Transmission of the entry data in
the fragmented mode
Result data 1
Entry information 8 bytes max.
Result data 2
Entry information 16 bytes max.
Result data 3
Entry information 32 bytes max.
Result data 4
Entry information 48 bytes max.
Result data 5
Entry information 64 bytes max.
DCR 248i
Parameter
Inp. data Outp.
1
1
1
3
1
0
0
11
0
19
0
35
0
51
0
67
PROFINET
data
1
0
3
0
0
0
0
0
59