10.4.22 Module 61 - Device application status and control
PROFINET-IO module identifier
• Module ID: 1061
• Submodule ID: 1
Description
From the viewpoint of the communication, the module contains generic status and control information
which can be interpreted for each device in the GSDML file and in the device application.
Tab. 10.34:
Input data structure module 61
Input data
Reserved
Positive de-
coding
Negative de-
coding
Pos. ref.
comparison
Neg. ref.
comparison
Reserved
Input data length: 2 bytes
Tab. 10.35:
Output data structure module 61
Output data
Not used
Auto-setup
Reference
code teach
Not used
Output data length: 2 bytes
10.4.23 Module 74 – I/O status and control
PROFINET-IO module identifier
• Module ID: 1074
• Submodule ID: 1
Description
The module defines the handling of switching input and switching output signals.
Tab. 10.36:
Input data structure module 74
Input data
State 1
State 2
Leuze electronic
Address
Data type
0
Byte
1.0
Bit
1.1
Bit
1.2
Bit
1.3
Bit
1.4-1.7
Bits
Address
Data type
0
Byte
1.0
Bit
1.1
1.2-1.7
Bit Area
Address
Data type
0.0
Bit
0.1
Bit
Value range
Default
---
0
0, 1
0
0, 1
0
0, 1
0
0, 1
0
---
0
Value range
Default
0
0->1: Error Ac-
knowledge
1->0: Error Ac-
knowledge
0
Value range
Default
0.1
0
0.1
0
DCR 248i
Unit
Explanation
---
Reserved
---
Decoding order com-
pleted successfully
---
Decoding order NOT
completed successfully
---
Positive reference
code comparison
---
Negative reference
code comparison
---
Reserved
Unit
Explanation
---
---
This control bit starts
the auto setup function.
---
This control bit starts
the teach function.
---
Unit
Explanation
---
Signal state of the
switching input 1.
---
Signal state of the
switching input 2.
PROFINET