Module 28 - Result Data 8 - Leuze electronic DCR 248i Original Operating Instructions

Camera-based code reader
Table of Contents

Advertisement

Tab. 10.14:
Input data structure module 27
Input data
Activation
status
Reserved
User data re-
sult or Cmd
interpreter re-
sponse
Further re-
sults in the
buffer
Buffer over-
flow
New result
Reserved
Waiting for
acknowledg-
ment
Result data
length
Data
Input data length: 3 bytes consistently + 128 bytes of result information
10.4.12 Module 28 – Result data 8
PROFINET-IO module identifier
• Module ID: 1028
• Submodule ID: 1
NOTICE
Ä Modules 21 ... 28 can only be used one at a time, not simultaneously.
Ä If the result information (result plus additional information, such as the code quality) does not
fit in the selected module width, the information is shortened.
The transmitted result data length is an indication of shortening of the result information.
Description
The module defines the transfer of the result data. The result data comes from the Formatter currently se-
lected. The Formatter can be selected and configured in the webConfig tool (see chapter 9.3 "webConfig
tool").
Leuze electronic
Address
Data type
0.0
Bit
0.1
Bit
0.2
Bit
0.3
Bit
0.4
Bit
0.5
Bit
0.6
Bit
0.7
Bit
1
UN-
SIGNED 16
3..130
128x
UN-
SIGNED8
Value range
Default
0: Deactivated
0
1: Activated
0
0: User data
0
1: Cmd inter-
preter response
0: No
0
1: Yes
0: No
0
1: Yes
0->1: New result
0
1->0: New result
0
0: Base state
0
1: Control waiting
for acknowledge-
ment from the
master
0-65535
0
0-FFh
0
DCR 248i
Unit
Explanation
---
Displays the current
activation status.
---
Free
---
Distinction between re-
sult from the Formatter
and answer from the
Cmd interpreter.
Makes the distinction
easy for the user.
---
Signal indicates
whether further results
are in the buffer.
---
Signal indicates that
result buffer is occu-
pied and the device re-
jects data.
---
The toggle bit indicates
whether a new result is
present.
---
Free
---
This signal represents
the internal state of the
control.
---
Data length of the ac-
tual result information.
---
Result information with
a length of consistently
128 bytes.
PROFINET
70