7.5

Cable lengths and shielding

Observe the maximum cable lengths and the shielding types:
Connection
DCR 200i host
Network from the first
DCR 200i to the last net-
work participant
Switching input
Switching output
DCR 200i power supply
unit
7.6

Connecting code reader to fieldbus

The code reader can be connected to the following fieldbuses via the MA 2xxi modular connection units:
• CANopen: MA 235i
• EtherCAT: MA 238i
• EtherNet/IP: MA 258i
• DeviceNET: MA 255i
• PROFIBUS: MA 204i
• PROFINET: MA 248i
NOTICE
Ready-made cables are available for connecting the code reader to a modular connection unit
(see chapter 16.4 "Cables accessories").
7.7
Connecting code reader to MA 150 connection unit
The signals from the code reader are distributed in the machine decentrally via the MA 150 modular con-
nection unit. The following components can be connected to the MA 150 connection unit:
• Code reader of the DCR 200i series
• Photoelectric sensor/diffuse sensor to activate the code reader
• Voltage supply
• External illumination
• Serial communication RS 232/RS 422
Leuze electronic
Interface
RS 232
RS 422
Ethernet
DCR 248i
Max. cable length
10 m
1200 m
(dependent on baud
rate)
Max. segment length:
100 m for 100BASE-TX
twisted pair (min. CAT 5)
10 m
10 m
30 m
Electrical connection
Shielding
Shielding absolutely nec-
essary
RS 422 conductors,
stranded in pairs
Shielding absolutely nec-
essary
Not necessary
Not necessary
Not necessary