10.4.14 Module 102 – Entry data 2
PROFINET-IO module identifier
• Module ID: 1102
• Submodule ID: 1
NOTICE
Ä Data reset does not affect the output data toggle bits
Ä If fragmentation is used, the application must set the output data of the entry data fragmen-
tation module for each fragment that is to be transmitted before the toggle bit is toggled in
the entry data module (see chapter 10.4.4 "Module 16 – Fragmented entry").
Description
The module defines the transfer of entry data to a command interpreter (Cmd interpreter) in the device.
Tab. 10.18:
Input data structure module 102
Input data
Data accep-
tance toggle
bit
Data rejec-
tion toggle bit
Reserved
Error code
Input data length: 1 byte
Tab. 10.19:
Output data structure module 102
Output data
Reserved
Leuze electronic
Address
Data type
0.0
Bit
0.1
Bit
0.2
Bit
0.3
Bit
0.4-0.7
Bit
Address
Data type
0.0
0.1
0.2
0.3
0.4
Value range
Default
0->1: Data have
0
been accepted
1->0: Data have
been accepted
0->1: Data have
0
NOT been ac-
cepted
1->0: Data have
NOT been ac-
cepted
0
0
0: No error
0
1: Receive buffer
overflow
2: Sequence er-
ror
3: Invalid length
entry
4: Invalid frag-
ment length entry
5: Length change
in a sequence
Value range
Default
0
0
0
0
0
DCR 248i
Unit
Explanation
---
The signal shows that
the device has ac-
cepted the data or the
data fragment.
---
The device has re-
jected the acceptance
of the data or the data
fragment.
---
Free
---
Free
---
Cause of error for re-
jection of the fragment.
Unit
Explanation
Free
Free
Free
---
Free
---
Free
PROFINET
73