Download Print this page

OmniPod PODDER Resource Manual page 12

Insulin management system
Hide thumbs Also See for PODDER:

Advertisement

OMNIPOD
SYSTEM INSTRUCTIONS |
®
Important PDM tips and reminders.
These tips are intended for use only with PDM models ATT400, DET400,
DET450, DET456, ENT450, FRT400, FRT456, ITT456 and NLT450. The PDM
model number is found on the back of the PDM next to the REF symbol.
How to view insulin records.
15:00 15/5
Bolus
More actions
Temp basal
My records
Settings
Suspend
Status
Select
Select
1. On the home screen,
select My records.
How to view multiple-day BG trends.
15:00 15/5
Bolus
More actions
Temp basal
My records
Settings
Suspend
Status
Select
Select
1. On the home screen,
select My records.
How to change existing basal rate.
NOTE: Insulin delivery must be suspended before changing basal rates.
15:00 15/5
Bolus
More actions
Temp basal
My records
Settings
Suspend
Status
Select
Select
1. On the home screen,
select Settings.
15:00 15/5
Segment: 15:00-24:00
Enter basal rate.
0.75
U/hr
Back
Enter
Enter
5. Enter the basal rate
for the edited segment and
then, press Enter.
The values shown here are for illustrative purposes only. Actual screens may vary based on user settings and country. Consult with your healthcare professional before
Important tips and reminders
15:00 15/5
Insulin delivery
BG history
Alarm history
Carb history
All history
My info
Back
Select
Select
2. Select Insulin delivery.
15:00 15/5
Insulin delivery
BG history
Alarm history
Carb history
All history
My info
Back
Select
Select
2. Select BG history.
15:00 15/5
Basal Programs
Presets
System setup
Vibration
Back
Select
Select
2. Select Basal Programs.
15:00 15/5
basal 2:
Segment
U/hr
[add new]
00:00-08:00
0.60
08:00-15:00
0.80
15:00-24:00
0.75
Daily basal: 17.15
U
Cancel
New
Save
Save
6. Press Save.
15:00 15/5
Insulin totals:
15/5/18
Bolus (52%)
23.90
U
Basal (48%)
22.30
U
Total daily
46.20
U
Back
Bolus
Basal
3. The PDM provides a summary of
today's information including total
boluses, total basal and total daily doses.
Use the Up/Down controller buttons
to view the summary for previous.
15:00 15/5
1-day (n=7)
15/5/18
Avg BG: 6.1
mmol/L
Min/max: 2.1/8.4
mmol/L
BG goal: 4.4-7.8
mmol/L
Within goal: 57%
Above goal: 29%
Below goal: 14%
Back
Trends
Trends
List
3. Press Trends to show
the BG data for the
past 7 days.
15:00 15/5
Basal Programs
basal 1
basal 2
[add new]
Back
Enable
Select
Select
3. Select the basal programme
to be edited. On next screen,
select the segment to be edited
and then, press Edit.
15:00 15/5
Press "Save" to update
"basal 2."
1.00
0.50
0.00
12a
6a
12p
6p
12a
Daily basal: 17.15
U
Cancel
Save
Save
List
7. Press Save. For additional edits,
repeat steps 3-8.
Important reminder
During the activation
and priming of the Pod,
the PDM and the Pod
should be adjacent and
in contact. Please refer
to the Omnipod
®
Insulin
Management System
User Guide for a full set
of instructions.
15:00 15/5
7 day (n=52)
Avg Reads/day: 7
Avg BG: 7.5
mmol/L
Min/Max: 2.1/19.4
mmol/L
BG goal: 4.4-7.8
mmol/L
Within goal: 48%
Above goal: 33%
Below goal: 19%
Back
14 day
Graph
4. Continue pressing the
middle soft key to show
the trends for previous
14, 30, 60 and 90 days.
15:00 15/5
Enter start time for this
basal Segment.
15:00
Back
Next
Next
4. Enter the start time and
then, press Next and repeat
for end time.

Advertisement

loading
Need help?

Need help?

Do you have a question about the PODDER and is the answer not in the manual?

Questions and answers