3.5 Gas connection

Connection with copper pipe:
The connection to the gas supply mains
must be made so that no stresses or strains
of any kind are applied to the appliance. The
connection can be made using the adapter unit
D with two conical elements, always fitting the
gasket C supplied.
Connection with steel hose:
Use only continuous-wall stainless steel hoses
compliant with the relevant regulations, and
always fit the gasket C supplied between the
fitting A and the hose E.
When connecting with a hose, ensure that
the total length of the pipeline is not more
than 2 metres; also Ensure that the hoses do
not touch moving parts and are not crushed.
INSTRUCTIONS FOR THE INSTALLER
4. ADAPTING TO DIFFERENT TYPES OF
GAS
Before carrying out the operations described
below, disconnect the appliance from the
electricity supply.
The appliance is tested with G20 (2H) natural
gas at the pressure of 20 mbar. If it is to be used
with other types of gas, the burner nozzle has
to be changed and the gas valve adjusted. To
replace the nozzle, proceed as described below.

4.1 Adjusting the oven burner

To adjust the oven burner, open the oven door
and proceed as follows:
• Remove all accessories (pans, shelves and
any steel runners);
• Lift the oven bottom plate and extract it so
that the inside of the oven is as shown in
the picture.

4.1.1 Adjusting the minimum setting

The oven thermostat has a screw for regulating
the minimum setting,accessed by removing
the thermostat knob. When the type of gas
used changes, the minimum setting must be
adjusted as follows:
• Light the oven burner and keep it operating
at the highest setting for 10/15 minutes
with the door closed.