Performance
- continued
ENVIRONMENTAL CHARACTERISTICS
The 2A60 was engineered
before
design
goals
for
environmental
characteristics
were established.
The performance
requirements
given
in the environmental
characteristic
sheet
are the most accurate
figures
available
without
performing
extensive
environmental
tests.
They are
to be used as a guide
not as an
instrument
specification
.
Characteristic
Performance
Reauirement
Sunnlemental
Tn-Fnrme,t-;,-m
Temperature
Nonoperating
-40 to +65°C
Derate
maximum operating
Operating
Same as oscilloscope
used to
temperature
by 1°C/1000
display
signal
above 5000 ft.
Altitude
Nonoperating
50,000
ft.
Operating
10,000
ft.
Vibration
Operating
0.015
inch pk-pk
10-50-10
cps
(1.
9G), 15 min
each axis,
three
minutes
at
resonance
or 50 cps,
55
minutes
total
Shock
30G's,
1/2 sine,
llms;
one
Nonoperating
shock in each direction
of the
three
axes;
total
of six
shocks
Humidity
Nonoperating
Transportation
Package
Vibration
Qualifies
under
NSTC test
Package
Drop
procedure
lA, Category
II
(24 inch
drop)
ft
2
1-23-68