Agilent Technologies E5022B Programming Manual page 153

Hard disk read/write test system
Hide thumbs Also See for E5022B:
Table of Contents

Advertisement

Direction
• lostSector
Description
Direction
Return Values
Completion Code
VI_SUCCESS
Error Code
hpe5022_ERROR_INV_ID
hpe5022_ERROR_INACCURATE_BER
hpe5022_ERROR_DATA_CORRUPT
hpe5022_ERROR_NOT_INIT
See Also
"hpe5022_BER_measureBer" on page 113
"hpe5022_BER_setupBer" on page 116
Chapter 3
Bit Error Rate Measurement Function
sectors include the number of lost sectors.
OUT
Returns the number of lost sectors. Lost sector represents the
sector where a synchronized pattern is not found.
OUT
Description
No Error
Description
The handle specified by 'id' is invalid.
The 'ber' and 'symbol' results are not
accurate because there are too many
errors to counts.
The bit error measurement data is corrupt.
Check if your measurement sequence is
correct.
The resource of E5039A/B can not be
opened during initialization. Check if
E5039A/B is included in the rsrcArray of
the "hpe5022_init" function.
Function Reference