Integrated Dc Power Supply - Siemens SIMOTION P320-4 E Manual

Table of Contents

Advertisement

9.6

Integrated DC power supply

Technical specifications
DC power supply
Input voltage
Power consumption
Power failure buffering
Maximum continuous output power
Degree of protection
Protection class
The power specifications apply to the power supply component not to the device.
1
Note
Inrush current
The device requires an inrush current of at least 6.5 A for 50 ms.
The peak value of the startup current depends on the input voltage and the impedance of the
24 V power source. Peak currents greater than 6.5 A are possible. This will not have a negative
impact on device functionality.
SIMOTION P320-4 E / P320-4 S
Manual, 03/2018, A5E36004933B
1
1
9.6 Integrated DC power supply
24 V DC (-20%/+20%)
Max. 90 W
hold-up time = 20 ms at 20.4 V
(DC_FAIL is active after > 5 ms)
80 W
IP 20
Protection class I (a protective conductor must be
connected to the device)
Technical data
141

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simotion p320-4 sSimotion p320-4 e

Table of Contents