Installation/mounting

6.2 Permissible mounting positions

6.2
Permissible mounting positions
Note
The SIMOTION P320-4 is approved for operation in closed rooms only.
Ensure the required minimum clearance to other components or enclosure panels:
● Below at least 100 mm
● Above at least 50 mm
The permissible mounting positions for the SIMOTION P320-4 are standard rail mounting and
vertical mounting.
Standard rail mounting
Horizontal mounting is the preferred position.
The following horizontal mounting option is permitted:
The interfaces are at the bottom.
The figure shows the interfaces on the front for
representation purposes only.
For rail mounting, the interfaces always point
downward.
You can find mounting information under Standard rail mounting (Page 105).
104
SIMOTION P320-4 E / P320-4 S
Manual, 03/2018, A5E36004933B