Adjust Feed Rate; Adjust Stroke Length; Calculate Output - Graco Mongoose Series Instructions - Parts Manual

Chemical metering pump
Table of Contents

Advertisement

Operation

Adjust Feed Rate

The Mongoose pump allows for the exact setting of the
pump's SPEED knob (H) on the pump's control panel.
See F
. 5.
IG
H
F
. 5: Mongoose Control Panel
IG
NOTE: Standard cycles per minute settings available
are: 1, 2, 3, 4, 5, 6, 7, 8, 10, and increase by 5 thereafter
up to the maximum of 125.
10

Adjust Stroke Length

The stroke length can be adjusted on the Mongoose
pump. This is a mechanical adjustment made using
STROKE % knob (J) on the control panel.
To avoid damage to the pump, this adjustment
should only be made while the pump is running at a
high-stroking rate.

Calculate Output

J
A pump's output per minute can be determined by divid-
ing the maximum rated gallons per day by 1440 (min-
utes per day).
For example, a 30 gallons per day (gpd) pump at a max-
imum stroke length and speed setting of 125 cycles per
minute (cpm) will pump 0.000167 gallons per stroke
(gps).
30 gpd ÷ 1440 min/day = 0.0208 gpm ÷ 125 spm =
With this value and the pump's speed setting (cycles per
minute) you can calculate your pump's output at it's
rated pressure.
A 30 gpd pump set at 50 cycles per minute:
50 cpm x .000167 gps x 1440 min/day = 12.02 gpd
Reducing the stroke length will reduce the pump's out-
put again. If the example pump above had it's stroke
length reduced to 50% the 12.02 gallons per day output
is reduced to 6.01. (Example: 12.02 gpd x 0.50 = 6.01
gpd).
A higher product viscosity will reduce the output. Pres-
sures lower than the pump's rating can increase the out-
put.
NOTICE
0.000167 gal/stroke
3A4131H