3 Wiring

3.1 Voltage supply

voltage
12...24 V DC
LED -
readyness
fuse
10A T
For systems approved by classification societies, the voltage range 12V or has to
be selected. If the supply voltage exceeds or falls below the range by +30% or -
!
25% respectively, a corresponding error message will be issued.

3.2 Control head

Advice how to mount the connecting cable
loosen screws and
lift housing cover
The data cable must be prepared as shown above. The cables must not be
squeezed when assembling the components after the wiring.
!
The sealing of the housing must be fitted correctly to guarantee protection type
IP65.
voltage
voltage
12 V DC
24 V DC
7
7
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
2
1
earthing at one of the 4 mounting screws directly
(connection to ship mass)
preparation connection cable
7
7
1
2
switch for configuration
3
of engine type
4
(see chapter 2 overview)
5
6
7
8
2
supply line 2,5mm
,
length. 10m max
GND
screened
Vcc
fuse
+
main
16A T
switch
-
100 mm
male
shielded-
taper
cable
sleeving
12V / 24V DC
10 A nominal current
30 A peak current
(acc. to Lloyds Register)
sealing
pressure
insert
- s crew