Replacement Of Inlet-/Pressure Valves/Sleeves; Demounting/Mounting Of Cylinder Head/Cylinder Block - Alto DYNAMIC Standard Repair Manual

Table of Contents

Advertisement

DK
Udskiftning af suge-/trykventiler/-man chet ter
Afmontering/montering af top styk ke/cylinderblok
GB

Replacement of Inlet-/Pressure Valves/Sleeves

Demounting/Mounting of Cylinder Head/Cylinder Block

DE
Auswechselung der Saug-/Druckventile/-Manschetten
Montage/Demontage des Zylinderkopfes/Zylinderblocks
FR
Rempl. des soupapes d'aspiration/ de pression et des manchettes
Démontage / montage de la culasse/du bloc cylindre
DK
3 stk. bolte demonteres/monteres på pumpen. (20
Nm).
GB
Demount/mount 3 bolts on the pump (20 Nm).
DE
3 Stück Bolzen an der Pumpe demontieren/mon ti e ren.
(20 Nm)
FR
Dévisser / visser 3 boulons de la pompe (20 Nm).
DK
Ventilsæder demonteres med specialværktøj og kasse-
res. Nye ventiler monteres ved at trykke med fi ngrene.
GB
Demount valve seats with special tool - scrap them.
Mount new valves by pressing with your hands.
DE
Ventilsitze mit Spezialwerkzeug demontieren und
wegwerfen. Neue Ventile mit den Händen eindrücken.
FR
Démonter le siège de soupape à l'aide d'outillage
spécialisé, puis le mettre au rebut. Remonter des nou-
velles soupapes d'une pression des doigts.
30
DK
Topstykke samt cylinderblok demonteres/monteres.
GB
Demount/mount cylinder head and cylinder block.
DE
Zylinderkopf und Zylinderblock demontieren/mon ti e ren.
FR
Démonter / monter la culasse ainsi que le bloc cylindre.
DK
Vandmanchetter demonteres med specialværktøj. Nye
manchetter monteres.
GB
Demount water sleeves with special tool. Mount new
sleeves.
DE
Wassermanschetten mit Spezialwerkzeug demontier-
en. Neue Manschetten montieren.
FR
Démonter les manchettes à eau à l'aide d'outillage
spécialisé. Remonter des nouvelles manchettes.

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DYNAMIC Standard and is the answer not in the manual?

Questions and answers

John Baroi
March 23, 2025

The unit does not start

1 comments:
Mr. Anderson
March 23, 2025

The Alto DYNAMIC Standard unit may not start due to the following reasons:

1. Machine not plugged in – Ensure the machine is properly plugged into a power source.
2. Defective socket – Try using a different socket.
3. Blown fuse – Replace the fuse and turn off other machines that may be overloading the circuit.
4. Defective extension cable – Try running the machine without the extension cable.
5. Low voltage or low temperature – Activate the trigger of the spray handle to check if the machine starts.

If the issue persists after these checks, further troubleshooting or professional service may be required.

This answer is automatically generated

Antony Hargreaves
April 18, 2025

My alto Kew dynamic 7400 keeps stop starting and won’t stay on permanently. I’m not sure if this an issue with the lance or the machine.

1 comments:
Mr. Anderson
May 9, 2025

The Alto DYNAMIC Standard 7400 could be stopping and starting intermittently due to air in the inlet hose or pump, which causes the machine to pulsate. Letting the machine run can help remove the air. Other possible causes include a blown fuse, incorrect mains voltage, or the thermal sensor being activated.

This answer is automatically generated