Wear Parts - Alto DYNAMIC Standard Repair Manual

Table of Contents

Advertisement

Sliddele / Wear Parts / Verschleißteile / Pièces d'usure
Pos. no.
28
28
3
3
4
5
20
24
25
26
28
24
Betegnelse
Designation
Slange kompl., 10m
Hose compl.
Slange kompl., 12m
Hose compl.
Motor m. skråskive, (230V,50Hz)
Motor w. wobble disc
Motor m. skråskive, (240V,50Hz)
Motor w. wobble disc
Rep. sæt skråskive
Rep. kit wobble disc 140 bar
Rep. sæt leje
Rep. kit bearing
Rep. sæt automatisk s/s ventil
Rep. kit automatic s/s valve
Box m. kontakt & kabel
Box w. switch & cable
Rep. sæt tætningssystem
Rep. kit sealing system
Rep. sæt ventilsystem
Rep. kit valve system
3 x Blindprop m. O-ring
3 x Blind plug w. O-ring
Bezeichnung
Désignation
Schlauch kompl.
Tuyau compl.
Schlauch kompl.
Tuyau compl.
Motor m. Taumelscheibe komplett
Moteur avec disque obl. compl.
Motor m. Taumelscheibe komplett
Moteur avec disque obl. compl.
Rep. satz Taumelscheibe
Kit de rép. disque oblique
Rep. satz Lager
Kit de rép. palier
Rep. satz Ventil für S/S-Automatik
Kit, soupape marche/arrêt automatique
Gehäuse m. Schalter & Kabel
Boîte avec micro-switch & câble
Rep. satz Dichtungssystem
Kit de rép. système d'étanchéité
Rep. satz Ventilsystem
Kit de rép. système de soupape
3 x Blindpfropfen m. O-Ring
3 x Cache avec joint torique

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DYNAMIC Standard and is the answer not in the manual?

Questions and answers

John Baroi
March 23, 2025

The unit does not start

1 comments:
Mr. Anderson
March 23, 2025

The Alto DYNAMIC Standard unit may not start due to the following reasons:

1. Machine not plugged in – Ensure the machine is properly plugged into a power source.
2. Defective socket – Try using a different socket.
3. Blown fuse – Replace the fuse and turn off other machines that may be overloading the circuit.
4. Defective extension cable – Try running the machine without the extension cable.
5. Low voltage or low temperature – Activate the trigger of the spray handle to check if the machine starts.

If the issue persists after these checks, further troubleshooting or professional service may be required.

This answer is automatically generated

Antony Hargreaves
April 18, 2025

My alto Kew dynamic 7400 keeps stop starting and won’t stay on permanently. I’m not sure if this an issue with the lance or the machine.

1 comments:
Mr. Anderson
May 9, 2025

The Alto DYNAMIC Standard 7400 could be stopping and starting intermittently due to air in the inlet hose or pump, which causes the machine to pulsate. Letting the machine run can help remove the air. Other possible causes include a blown fuse, incorrect mains voltage, or the thermal sensor being activated.

This answer is automatically generated