Commands
Control Description
ERST ?
Error Status inquiry
LAMP ?
Input Source List inquiry
INST ?
NAME ?
Projector Name inquiry
Manufacturer's Name
INF1 ?
INF2 ?
Model Name inquiry
INFO ?
Other Information inquiry Returns an empty string.
CLSS ?
Class Information inquiry 2
(continued on next page)
LWU650-APS/LWU530-APS
User's Manual - Technical
Light Source
Status inquiry
inquiry
PJLink command (continued)
Parameter or Response
1st byte: Refers to Fan error; one of 0 to 2
2nd byte: Refers to Light Source error; one of
0 to 2
3rd byte: Refers to Temperature error; one of 0 to 2
4th byte: Refers to Cover error; one of 0 to 2
5th byte: Refers to Filter error; one of 0 to 2
6th byte: Refers to Other error; one of 0 to 2
The meaning of 0 to 2 is as given below
0 = Error is not detected; 1 = Warning; 2 =
Error
1st number (digits 1 to 5): Light Source Hours
2nd number : 0 = Light Source off,
1 = Light Source on
11 12 23 31 33 36 51
Responds with the name set in "PROJECTOR