5.2
Output types
..S.
Solid shaft
Fig. 8:
Output types
A detailed view of the gear unit can be obtained from the drawings in the gearunit documentation.
5.3
Housing
The housings are of cast iron. If required, they may also be of steel.
The housings of types B2.. and B3.. up to and including size 12 are manufactured as onepiece housings.
Type T3.. as well as sizes 13 to 28 of types B2.. and B3.. are provided with twopiece housings. The
housing is rigid in design and due to its form has excellent noise and temperature characteristics.
The gearunit housing comes with the following equipment:
Lifting eyes (adequately dimensioned for transport).
Inspection and/or assembly cover (for oil filling and/or inspection).
Oilsight glass or oil dipstick (to check the oil level).
Oildrain plug (for oil drain).
Air filter or breather screw (for aeration and ventilation).
Colour codes for ventilating, oil inlet, oil level and oil drainage:
Airrelief point: yellow
Oilfilling point: yellow
Oil level:
..F.
Flanged shaft
red
BA 5033 EN 03/2011
..H.
..D.
Hollow shaft
Hollow shaft
with
for
parallel keyway
shrink disk
Oildraining point:
Lubricating point:
Oil level:
24 / 96
..K.
H
ollow shaft with
internal spline
to DIN 5480
white
red
red