Bosch Rexroth AG
Assembly, Disassembly and Electrical Installation
10.4 VDP Assembly Dimensions
①
Mounting cut-out
Fig. 10-6: Assembly dimensions in millimetres
10.5 Disassembly
1. Disconnect the operating display
2. Remove all connected cables
3. Loosen the screws of the clamp fastenings.
4. Fold the clamp fastenings.
5. Press the click-in lug of the installation aid.
Fig. 10-7: Click-in lug
6. Remove the operating display from the mounting frame.
20/37
VDP 15.3, 18.3, 21.3 Multitouch
535 mm (VDP 21.3)
473 mm (VDP 18.3)
403 mm (VDP 15.3)
1
DOK-SUPPL*-VDPXX.3MTBU-IT02-EN-P