CHAPTER 6 - DETAILED PARAMETER DESCRIPTION
[Factory Setting]
Parameter
P296
(1)(2)
Nominal Voltage
nominal voltage of
6.4 - SERIAL COMMUNICATION PARAMETERS - P300 to P399
P308
(1)(2)
Soft-Starter Address
on the Serial
Communication
Network
P309
(1)(2)
Fieldbus
Communication
Board Enabling
P310
Profibus DP or DP-V1
Master Stop Detection
119
Range
Unit
Description / Notes
0 to 1
[ According to the
the Soft-Starter
SSW-06 ]
-
1 to 247
 Defines the Soft-Starter SSW-06 address on the serial Modbus-RTU
[ 1 ]
communication network.
1
 For more information, refer to the Serial Communication Manual
for the Soft-Starter SSW-06.
0 to 9
[ 0=Inactive ]
-
 Enables and defines the protocol type of the Fieldbus Communica-
tion Board.
 For more information, refer to the Fieldbus Communication Manual
for the Soft-Starter SSW-06.
0 to 1
[ 0=Inactive ]
1
 It allows, through the bit 6 of the control word, detecting that the
master of the Profibus DP or DPV1 is stopped. Refer to the Fieldbus
communication manual for more details.
 When it occurs it will indicate E29. In order to prevent the error, the
master must keep the bit 6 in 1.
ATTENTION!
Always program this parameter with a current that exactly
matches the current of the model of your Soft-Starter SSW-
06, described in the nameplate of the SSW-06. An error in
programming this parameter may damage your Soft-Starter
SSW-06.
P296
Voltage Range
0
1
Table 6.33 - Voltage range
ATTENTION!
Always program this parameter with a voltage that exactly
matches the voltage of the model of your Soft-Starter SSW-06.
P309
0
Inactive
1
Profibus-DP (1 Input and 1 Output)
2
Profibus-DP (4 Inputs and 4 Outputs)
3
Profibus-DP (7 Inputs and 7 Outputs)
4
DeviceNet (1 Input and 1 Output)
5
DeviceNet (4 Inputs and 4 Outputs)
6
DeviceNet (7 Inputs and 7 Outputs)
7
EtherNet (1 Input and 1 Output)
8
EtherNet (4 Input and 4 Output)
9
EtherNet (7 Input and 7 Output)
Table 6.34 - Fieldbus Communication Protocol Type
NOTE!
Without a Fieldbus Communication Board, this parameter
must remain at 0 (not used).
P310
Description
0
Inactive
1
Active
Table 6.35 - Selection of the Profibus DP master stop detection