Mains electricity connection

THIS APPLIANCE MUST BE CONNECTED TO THE MAINS SUPPLY
BY A COMPETENT PERSON, USING FIXED WIRING VIA A DOUBLE
POLE SWITCHED FUSED SPUR OUTLET AND PROTECTED BY A
3A FUSE.
We recommend that the appliance is connected by a qualified
electrician, who is a member of the N.I.C.E.I.C. and who will comply
with the I.E.E. and local regulations.
The wires in the mains lead of this
appliance are coloured in accordance
with the following code:
BLUE = NEUTRAL, BROWN = LIVE,
GREEN and YELLOW = EARTH.
As the colours of the wires in the mains lead for the appliance may
not correspond with the coloured markings identifying the terminals
connecting to the fused spur, proceed as follows:
The wire which is coloured GREEN and YELLOW must be connected
to the terminal which is marked with the letter (E) or by the Earth
symbol
The wire which is coloured BLUE must be connected to the terminal
which is marked with the letter (N), or coloured BLACK.
The wire which is coloured BROWN must be connected to the
terminal which is marked with the letter (L) or coloured RED.
10
or coloured GREEN and YELLOW.
DOUBLE POLE SWITCHED
FUSED SPUR OUTLET
USE A 3 AMP FUSE