Step 7
Drain the product from the syrup sampling valve into
a cup. Close the syrup sampling valve by turning the
handle to the center position.
Figure 36
Step 8
Stir the finished product. Pour a small amount of
product over the refractometer. The brix reading
should register 13 to 14. A reading higher than this
would cause a darker, richer product. The
refrigeration system would have to run longer to
freeze the excess syrup. A reading lower than this
could cause a freeze--up in the freezing cylinder
because of the excess water.
Figure 37
Operating Procedures
Step 9
To adjust the brix, turn the adjustment screw located
behind the drip tray shelf. Clockwise adjustments
increase the amount of syrup to water, and
counterclockwise adjustments decrease the amount
of syrup to water. Adjust the screw in small
increments and check the brix again.
Repeat this step until a correct brix reading is
registered.
Step 10
Once the proper brix has been achieved, turn the
handle "up" to allow product to flow to the mix tank.
26
Figure 38
Figure 39