Taylor C300 Original Operating Instructions page 18

Slush freezer
Hide thumbs Also See for C300:
Table of Contents

Advertisement

9.
BRL NOT COOLING -- A freezing cylinder
check has been established for the AUTO
mode of operation. If a freezing cylinder enters
the AUTO mode, the control will check product
temperature. After five minutes, it will again
check product temperature. If product
temperature does not drop in that five minute
time span, the freezing cylinder will shut down
and this message will appear on the fault
screen. For this check to be valid, the product
temperature must be above 40_F (4.4_C).
FAULT DESCRIPTION
L: BARREL NOT COOLING
R: NO FAULT FOUND
CLR
+ + +
10.
BRL TEMP 2 HIGH -- A maximum allowable
product temperature has been established to
prevent product from excessive heating. If the
product exceeds 120_F (49_C) temperature for
any reason (in any mode of operation), the
entire unit shuts down.
FAULT DESCRIPTION
L: BARREL TEMP 2 HIGH
R: NO FAULT FOUND
CLR
+ + +
Faults, when corrected, are cleared from the fault
description screen, with the following exception:
BRL NOT COOLING. This fault requires the
operator to press the OFF (<-- --) key (when in the
FAULT DESCRIPTION screen) in order for the fault
to discontinue.
To see if there is more than one fault in either
freezing cylinder, press the PRIME (+ + +) key. To
return to the OPERATOR MENU, press the MENU
(SEL) key once. To return to the Main Screen, use
the AUTO (-- -->) key to cycle to MENU ITEM A,
then press the MENU (SEL) key.
Important: To the Operator
Screen C is SET CLOCK. Use the AUTO (-- -->)
and OFF (<-- --) keys to place the cursor under the
element to be set (hours, minutes, month, day, or
year). Use the PRIME (+++) and BEATER (-- -- --)
keys to increment or decrement the value. Press the
MENU (SEL) key to advance to the Daylight Saving
Time screen.
Note: The clock is programmed with military time.
SET CLOCK
14:30
<- - - - - - - ->
This screen will appear if an invalid date is entered.
(example: If the date entered exceeds the days of
SEL
that month.)
SET CLOCK
14:30
This screen allows the Daylight Saving Time options.
If the Daylight Saving Time option is enabled, then
the time will be advanced by one hour at 2:00 a.m.
on the first Sunday in April, and will be retarded by
one hour at 2:00 a.m. on the last Sunday in October.
DAYLIGHT SAVING TIME
SEL
ENABLE
<- - - - - - - ->
Screen D is MANUAL DEFROST. This screen
allows the operator to manually defrost the left side
of the unit.
Place the cursor under YES, press the MENU (SEL)
key, and the command will be executed.
MANUAL DEFROST
LEFT SIDE
<- - - - - - - ->
14
6/25/01
+ + +
- - - - - -
02/31/01
INVALID DATE
DISABLE
YES
Model C300
SEL
SEL
SEL
NO
SEL

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents