Taylor C300 Original Operating Instructions page 28

Slush freezer
Hide thumbs Also See for C300:
Table of Contents

Advertisement

Press the MENU (SEL) key.
Move the cursor under the word "SANITIZE" by
pressing the OFF (<-- --)key.
RINSE / SANITIZE
RINSE
SANITIZE
- - - - - - - - - -
<- - - - - - - ->
Step 7
Pressing the MENU (SEL) key will give you the
option for sanitizing the left freezing cylinder. Move
the cursor under the word "YES". Pressing the
MENU (SEL) key at this time will start the flow of
sanitizing solution into the left freezing cylinder.
SANITIZE
LEFT
SIDE
<- - - - - - - ->
Repeat Steps 6 - - 7 for the right side freezing
cylinder.
SANITIZE
RIGHT SIDE
<- - - - - - - ->
Step 8
Open the prime plugs. When sanitizing solution fills
the freezing cylinders approximately 2/3 full, close
the prime plugs.
Figure 29
Operating Procedures
EXIT
SEL
YES
NO
- - - - - -
SEL
YES
NO
- - - - - -
SEL
24
Step 9
Continue filling the freezing cylinders with sanitizing
solution until the solution purges out of the relief
valve at the top of the mix tank, and begins draining
into the front drip tray. Press the OFF (<-- --) key.
Step 10
Press the BEATER (-- -- --) key. Agitate the solution
in the freezing cylinders for five minutes.
Figure 30
Step 11
With a pail beneath the door spouts, open the draw
valves and drain all the solution from the freezing
cylinders. Press the OFF (<-- --) key and close the
draw valves.
Figure 31
Step 12
Disconnect the syrup connectors in the sanitizing
solution.