The following tables show the parameters and values displayed by the terminal and the variables sent to supervisor.
kVent can be connected to various systems of supervision, in particular can be used the following communication protocols BMS on the
Ethernet port: Modbus® and BacNet™.
The Modbus® address is the address specified in the Modbus® frame.
BMS index meaning
IR
Input Register
HR
Holding Register
C
Coil
DI
Discrete Input

6.1 INFO menu in main mask

Mask
Description
code
Y00a
Supply temperature probe - Probe value
Y00a
Temperature setpoint
Y00a
Modulating heating output - Hardware value
Y00a
Modulating reverse output - Hardware value
Y00a
Modulating cooling output - Hardware value
Y00a
Modulating cooling/heating signal - Hardware value
Y00a
Modulating heat recovery output - Hardware value
Y00a
MixDampReq
Y00a
Modulating reheating output - Hardware value
Y00h
Supply air pressure probe - Probe value
Y00h
Supply air flow
Y00h
Modulating supply fan - Hardware value
Y00h
Supply fan - Value
Y00i
Exhaust air pressure probe - Probe value
Y00i
Return air flow
Y00i
Modulating return fan - Hardware value
Y00i
Return fan - Value
Y00j
Supply temperature probe - Probe value
Y00j
Return temperature probe - Probe value
Y00j
External temperature probe - Probe value
Y00j
Exhaust temperature probe - Probe value
Y00j
Heating water temperature probe - Probe value
Y00k
Preheater water temperature probe - Probe value
Y00k
After preheating temperature probe - Probe value
Y00k
thTune temperature value
Y00l
thTune humidity value
Y00l
Supply humidity probe - Probe value
Y00l
Suction temperature probe - Probe value
Y00l
Return CO2 sensor - Probe value
Y00l
Return VOC sensor - Probe value
Y00p
Digital input remote ON - Hardware value
Y00p
Digital input remote ON - Input value
Y00p
Digital input supply filter alarm - Hardware value
Y00p
Digital input supply filter alarm - Input value
Y00p
Digital input supply filter 2 alarm - Hardware value
Y00p
Digital input supply filter 2 alarm - Input value
Y00p
Digital input return filter alarm - Hardware value
Y00p
Digital input return filter alarm - Input value
Y00p
Digital Input door switch- Hardware value
Y00p
Digital Input door switch-Input value
Y00p
Digital Input recovery clogeed- Hardware value
Y00p
Digital Input recovery clogeed -Input value
Y00q
Digital input freeze alarm - Hardware value
Y00q
Digital input freeze alarm - Input value
Y00q
Digital input heating overload - Hardware value
Y00q
Digital input heating overload - Input value
Y00q
Digital input cooling alarm - Hardware value
Y00q
Digital input cooling alarm - Input value
Y00q
Digital input humidifier alarm - Hardware value
Y00q
Digital input humidifier alarm - Input value
Y00q
Digital input fire alarm - Hardware value
Y00q
Digital input fire alarm - Input value
Y00q
Digital input fan overload alarm - Hardware value
Y00q
Digital input fan overload alarm - Input value
Y00r
Digital input economy mode - Hardware value
Y00r
Digital input economy mode - Input value
Y00r
Digital input precomfort mode - Hardware value
Y00r
Digital input precomfort mode - Input value
Y00r
Digital input comfort mode - Hardware value
kVent – rel 3.1 – 22/06/2018
6.

PARAMETERS TABLE

BacNet index meaning
AV
Analog Value
IV
Integer Value
BV
Binary Value
PIV
Positive Integer Value
Type
Default
UoM
Real
°C
Real
°C
Real
%
Real
%
Real
%
Real
%
Real
%
Real
%
Real
%
Real
Pa
Real
m3h
Real
%
Bool
Real
Pa
Real
m3h
Real
%
Bool
Real
°C
Real
°C
Real
°C
Real
°C
Real
°C
Real
°C
Real
°C
Real
°C
Real
%rh
Real
%rh
Real
%rh
Real
ppm
Real
%
Bool
Bool
Bool
Bool
Bool
Bool
Bool
Bool
Bool
Bool
Bool
Bool
Bool
Bool
Bool
Bool
Bool
Bool
Bool
Bool
Bool
Bool
Bool
Bool
Bool
Bool
Bool
Bool
Bool
26
Range
R/W
R
SupplyTemp.ReadVal
R
R
HeatVlv.HW_Val
R
RevOutVlv.HW_Val
R
CoolVlv.HW_Val
Modul_CoolHeat_NoRev.HW_V
R
R
HeatRecovery.HW_Val
R
R
ReHeatVlv.HW_Val
R
SupplyAirP.ReadVal
R
R
ModulSupplyFan.HW_Val
R
R
ExhAirP.ReadVal
R
R
ModulExhFan.HW_Val
R
R
SupplyTemp.ReadVal
R
RetTemp.ReadVal
R
ExtTemp.ReadVal
R
ExhTemp.ReadVal
R
W_HeatCoilTemp.ReadVal
R
W_PreHeatCoilTemp.ReadVal
R
AfterPreHeatCoilTemp.ReadVal
R
R
R
SupplyHum.ReadVal
R
FreshAirHum.ReadVal
R
RetAirCO2.ReadVal
R
RetAirVOC.ReadVal
R
RemoteOn.HW_Val
R
RemoteOn.ReadVal
R
SupplyAlrmFilter.HW_Val
R
SupplyAlrmFilter.ReadVal
R
SupplyAlrmFilter_2.HW_Val
R
SupplyAlrmFilter_2.ReadVal
R
ReturnAlrmFilter.HW_Val
R
ReturnAlrmFilter.ReadVal
R
Door_Switch.HW_Val
R
Door_Switch.ReadVal
R
Recovery_clogeed.HW_Val
R
Recovery_clogeed.ReadVal
R
FreezeHeat_Alrm.HW_Val
R
FreezeHeat_Alrm.ReadVal
R
DIN_AlHeat.HW_Val
R
DIN_AlHeat.ReadVal
R
CoolAlrm.HW_Val
R
CoolAlrm.ReadVal
R
HumAlrm.HW_Val
R
HumAlrm.ReadVal
R
DIN_Fire.HW_Val
R
DIN_Fire.ReadVal
R
DIN_FanOvld.HW_Val
R
DIN_FanOvld.ReadVal
R
DIN_Eco.HW_Val
R
DIN_Eco.ReadVal
R
DIN_PreComf.HW_Val
R
DIN_PreComf.ReadVal
R
DIN_Comf.HW_Val
Variable Name
BMS
IR18
TempRegSetP
IR1
IR19
IR20
IR21
IR22
al
IR23
MixDampReq
IR24
IR25
IR74
SupplyAirFlow
IR75
IR76
SupplyFan.Ctrl
DI5
IR77
ExhAirFlow
IR78
IR79
ExhFan.Ctrl
DI6
IR18
IR80
IR81
IR82
IR83
IR84
IR85
Temp_THTN_1
IR86
Hum_THTN_1
IR87
IR88
IR89
IR90
IR91
DI13
DI14
DI15
DI16
DI17
DI18
DI19
DI20
DI1435
DI1436
DI1433
DI1434
DI21
DI22
DI23
DI24
DI25
DI26
DI27
DI28
DI29
DI30
DI31
DI32
DI33
DI34
DI35
DI36
DI37
BacNet
AV18
AV1
AV19
AV20
AV21
AV22
AV23
AV24
AV25
AV74
AV75
AV76
BV172
AV77
AV78
AV79
BV176
AV18
AV80
AV81
AV82
AV83
AV84
AV85
AV86
AV87
AV88
AV89
AV90
AV91
BV198
BV199
BV200
BV201
BV202
BV203
BV204
BV205
BV1457
BV1458
BV1455
BV1456
BV206
BV207
BV208
BV209
BV210
BV211
BV212
BV213
BV214
BV215
BV216
BV217
BV218
BV219
BV220
BV221
BV222

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents