01026018
26
Failure to refill brine tank. Refill re-
strictor plugged.
No Refill
Air in brine line cause float to slam
shut.
Main board is not receiving a signal from
No Remote Signal
the remote.
The controller is seeking a known
valve position before/during/after a
Pos Sensor Err/
regen, or during progressive flow, but
Motor Position Error
cannot find it (this error does NOT
appear during initialization).
Total gallons through the secondary
filter (i.e. "Big Blue" filter) has ex-
Replace Ext Filt
ceeded the specified capacity of the
Big Blue.
Brine tank has low concentration of
Salt Bridging
brine, but solid salt exists above the
liquid brine level.
Clean or replace refill restrictor.
Verify all tubing connections are properly assembled.
Remote is off, out of range or on a different channel from
the main board. If interference is suspected, try moving the
remote closer or switching to a different channel on both the
main and remote units
Check connections of motor and position sensors at
both the motor and GBE board.
Replace optional filter cartridge. Reset the external
filter media life at Main Menu/ Accessories/ Ext.
Filter menu
Use a tool to break up any salt bridge inside the
brine tank