Troubleshooting Guide
Use This Chart to Diagnose Operation Issues
Problem
Mixer Will
Not Start
Motor
Runs Hot
Mixer Will
Not Reach
Correct Speed
Shaft Will
Not Fit
Into Drive
Shaft
Vibration
Noisy
Operation
Oil
Leakage
Bearing
Failure
R16 122016
Possible Cause
Loose connections
Incorrect wiring
Blown fuse
Wrong size heaters in starter
Mechanical jamming
Water damage to motor
Restricted ventilation
Amperage overload
Low or high voltage
Unbalanced voltage between phases
Frequent starting and stopping
Product too viscous
Impeller(s) upside down
Incorrect rotation
Overload of motor
Loose drive coupling bolts
Also See: "Mixer Will Not Start"
Shaft over size (proper diameter: 0.001" –
0.002" under normal diameter)
Wrong end of shaft (only one end fits)
(2) Coupling bolts are too tight
Wrong size shaft, coupling or bearing
Damaged shaft, coupling or bearing
Unstable mounting platform
Bent mixer shaft
Bent or uneven impeller blades
Impeller not immersed in liquid
Impeller too close to surface
Worn or damaged drive bearings
Foreign material in lubricant
Dry lip seal in spool
Insufficient lubricant
Incorrect lubricant
Loose drive coupling bolts
Worn or faulty bearings/gears
Damaged broken gasket
Excessive lubricant
Seals worn or damaged
Loose bolts around side plates
Water damage
High temperature product
Also See: "Noisy Operation"
Possible Solution
Check and tighten connection
Check wiring diagram and wire correctly
Replace fuse
Replace heaters
Free all debris for rotation
Service or replace motor
Clear the vents
C
ONSULT FACTORY
Wire for correct voltage
Consult electrician
Check with factory – a special motor may be
required
Check viscosity and specific gravity of product
(consult factory)
Reinstall in correct position
Change motor leads per nameplate instructions
Check amperage against nameplate data
Check coupling bolt tension (coupling and/or shaft
may be damaged if mixer has been run with slipping
coupling)
Measure and consult factory
Install end marked motor end
Loosen bolts
C
ONSULT FACTORY
C
ONSULT FACTORY
Reinforce platform
C
ONSULT FACTORY
C
ONSULT FACTORY
Fill tank
Fill tank and lower impeller (see S3)
Replace damaged parts
Change lubricant
Apply lubricant to lip seal
Fill proper amount of lubricant
Change to correct lubricant
Check and tighten coupling bolts
Check bearings/gears – replace if necessary
Replace gasket
Check manual for proper amount of lubricant and
drain excess
Replace seals
Check and tighten bolts
Replace bearings (check all other parts)
Provide heat shield
C
ONSULT FACTORY
15