Lubrication
Air Motor Connection
Air Motors must always have a filter, lubricator and moisture trap installed on the air supply line. Supply pipe should be
one size larger than the intake port on the motor. A regulator may be installed to control motor speed. Install the airline on
the correct port on reversible motors for proper rotation direction.
Gear Driven
Gear Driven mixers are lubricated at the factory using the proper type and amount of lubricant for normal service. For
additional information contact Dynamix Agitators.
Air Motor
Air Motor lubricator should be adjusted to feed one drop of oil every 50-75 CFM.
Use SAE #10automotive detergent engine oil.
Mixer Shaft Bearings
Mixer Shaft Bearings are pre-lubed and sealed and do not require re-lubrication.