Code
Error Description
8
Coolant timed out
FID Flame out
15
Front FID Flameout
16
Middle FID Flameout
17
Back FID Flameout
18
Front TCD Air Leak
19
Middle TCD Air Leak
20
Back TCD Air Leak
Injector EFC Flow Out of Range
35
Front EFC Flow Out of Range
36
Middle EFC Flow Out of Range
37
Back EFC Flow Out of Range
Injector EFC Pressure Out of Range
38
Front EFC Pressure Out of Range
39
Middle EFC Pressure Out of Range
40
Back EFC Pressure Out of Range
Injector EFC Flow ready time out
41
Front EFC Flow Ready Time Out
42
Middle EFC Flow Ready Time Out
43
Back EFC Flow Ready Time Out
Injector EFC Pressure ready time out
44
Front EFC Pressure Ready Time Out
45
Middle EFC Pressure Ready Time Out
46
Back EFC Pressure Ready Time Out
FID Flame Ignition
47
Front FID Flame Reigniting
48
Middle FID Flame Reigniting
1
If the used gas is Hydrogen (H
) the Error level is Error, in all other cases an Alert is given.
2
SCION Instruments
Error level
Event
Alert
Alert
Alert
Event
Event
Event
Alert/Error 1
Alert/Error1
Alert/Error1
Alert/Error 1
Alert/Error
Alert/Error 1
Alert/Error
Alert/Error
Alert/Error
Alert Error
Alert Error
Alert Error
436-GC/456-GC Service Manual Revision B February 2019
Cause Condition(s)
Column oven standby EFC21 (gas saver)
FID signal is < than given threshold
No gas supply, flow 0.0 mL/min
FID signal is < than given threshold
No gas supply, flow 0.0 mL/min
FID signal is < than given threshold
No gas supply, flow 0.0 mL/min
TCD Air Leak
Air Leak
Air Leak
Air Leak
Flow is above max+10% or below -5kPa for more
than 10 seconds
Flow is above max+10% or below -5kPa for more
than 10 seconds
Flow is above max+10% or below -5kPa for more
than 10 seconds
Pressure is above max+10% or below -5kPa for more
than 10 seconds
Pressure is above max+10% or below -5kPa for more
than 10 seconds
Pressure is above max+10% or below -5kPa for more
than 10 seconds
Unit not ready for 10 minutes
Unit not ready for 10 minutes
Unit not ready for 10 minutes
Unit not ready for 10 minutes
Unit not ready for 10 minutes
Unit not ready for 10 minutes
Page: 61
GC action
Action needed
Notification Message
Activate method, clear timeout
Notification Message
Ignite FID flame, check EFC flow
Auto-re-ignite
(gas supply), set FID gasflows
Notification Message
Ignite FID flame, check EFC flow
Auto-re-ignite
(gas supply), set FID gasflows
Notification Message
Ignite FID flame, check EFC flow
Auto-re-ignite
(gas supply), set FID gasflows
TCD Power off, Electronics off
Check for TCD air-leak
TCD Power off, Electronics off
Check for TCD air-leak
TCD Power off, Electronics off
Check for TCD air-leak
Activated Safety Method
Check EFC flows (gas supply)
Activated Safety Method
Check EFC flows (gas supply)
Activated Safety Method
Check EFC flows (gas supply)
Notification Message
-
Notification Message
-
Notification Message
-
Check gas supply, set desired
Activated Safety Method
pressure, check EFC device,
reboot GC
Check gas supply, set desired
Activated Safety Method
pressure, check EFC device,
reboot GC
Check gas supply, set desired
Activated Safety Method
pressure, check EFC device,
reboot GC
Activated Safety Method
-
Activated Safety Method
-
Activated Safety Method
-