Commissioning & Adjustments
Commissioning & Adjustments

Information on Language Setting

If a particular language is not available, set the operating language to English.
Available languages:
English
German
French
Italian

Starting up the Room Temperature Controller

1. Turn on the ON/OFF switch on the boiler control unit.
The following information appears in sequence:
• Segment test (all symbols are displayed)
• Equipment code and software version (10.62 or higher)
• "OPEN THERM"
If "0 - 10 V" appears here, set "OPEN THERM" See page 8
• If "OT CONTROL" flashes, make the following settings:
2. Change settings with +/- or the rotary selector, confirm with OK
• Select the operating mode:
• For weather-compensated mode: "OT CONTROL". An outside temperature sensor must be
connected to the boiler
• For room temperature-dependent mode: "ROOM CONTROL"
• "LANGUAGE"
• "YEAR"
• "MONTH"
• "DAY"
• "HOUR"
• "MINUTE"
Commissioning is complete when the current room temperature appears.
For further settings, see below.
Note: The automatic Summer/Wintertime changeover can be set under "SU/WI RULE"

Further Settings

1. Press MODE
2. Use <--/--> to select "SETTINGS"
3. OK to confirm
4. Use <--/--> to select "SERVICE"
Dutch
Polish
Spanish
Czech
Hungarian
5. OK to confirm
6. Use <--/--> to select the required setting
See the following chapters
7. OK to confirm