Commissioning The Vitotrol 100; Commissioning The Wireless Receiver; Checking The Reception Quality - Viessmann VITOTROL 100 Installation And Service Instructions Manual

Table of Contents

Advertisement

Commissioning the Vitotrol 100

Fig. 9

Commissioning the wireless receiver

A
8
Q ë r w
Fig. 10
LED:
A
Operating display
Address recognition
Service function
Heat demand for central heating
r
Heat demand for DHW heating
B
Service button

Checking the reception quality

1. Hold down service button
receiver (see fig. 10) for approx. 5 s, until LED
flashes.
2. Open the flap of the Vitotrol 100.
3. Press
twice.
4. Use / to select "Settings".
5. Confirm with OK.
B
on the wireless
B
1. Open the cover flap.
2. With a pointed object, press "Reset".
3. Use / to select the language.
4. Confirm with OK.
5. Use / to set the current date and time.
6. Confirm with OK.
Several Vitotrol 100 devices with wireless receivers
can be installed in one building. Each Vitotrol 100 can
only communicate with its allocated wireless receiver.
Note
If LED r flashes, the wireless receiver has not recog-
nised the signal from the Vitotrol 100. In this event,
change the address code (see page 15).
6. Use / to select "Service".
7. Press OK 4 times to confirm.
"Transmitting" appears on the display.
The transmission takes approx. 30 s.
If the reception quality is sufficient, LED
green. If the LED illuminates red, check the installation
location of the Vitotrol 100, change it if required and
check the reception quality again.
Commissioning
illuminates
13

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Utdb-rf2

Table of Contents