Advertisement

PW336i Hardware User Manual
PONOVO POWER CO., LTD
No. 139 Jinghai Third Road, BDA, Beijing, China, 100176
Office
TEL. +86 (10) 59089666
Info@relaytest.com
E-Mail
www.relaytest.com / www.ponovo.com.cn
Website
VERSION:
DATE :
This manual is the publisher of PONOVO POWER CO., LTD. To make any kind of copy of this
manual please contact PONOVO POWER CO., LTD in advance.
This manual represents the technical status for the moment of publishing. The product information,
description and specifications mentioned in the manual do not have any contact binding force and
PONOVO POWER CO., LTD remains the right to make modifications to the technical
specifications and configurations without prior notice. PONOVO POWER does not take
responsibility to the possible error/mistakes in this manual.
PW336i
HARDWARE USER MANUAL
PW336i-AE-3.30
JUNE 2018
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PW336i and is the answer not in the manual?

Questions and answers

Summary of Contents for Ponovo PW336i

  • Page 1 DATE : JUNE 2018 This manual is the publisher of PONOVO POWER CO., LTD. To make any kind of copy of this manual please contact PONOVO POWER CO., LTD in advance. This manual represents the technical status for the moment of publishing. The product information, description and specifications mentioned in the manual do not have any contact binding force and PONOVO POWER CO., LTD remains the right to make modifications to the technical...
  • Page 2: Table Of Contents

    PW336i Hardware User Manual Contents 1. Preface ……………………… Accessories…………………… … 2. Safety precaution …………. 9.1 PGPS02-GPS-based Synchronization device …….………………………………24 3. Designed applications …… 9.2 PIRIG-B Based Synchronization 4. Operation preparation …… device……………………….. ……………24 4.1 Preparation …………………. 9.3PSS01 Circuit Breaker Simulator... 25 4.2 Connecting PC ……………..
  • Page 3: Preface

    PW336i Hardware User Manual 1.Preface This manual gives detailed introduction to At the test site user should also refer to other PW336i so that user can have the reasonable, safety and test regulations required by his effective and safe operation of this test kit.
  • Page 4: Safety Precaution

    PW336i Hardware User Manual 2.Safety precaution In case the power outlet for powering up the PW336i does not have protective ground users must connect the ground socket of PW336i to the protective ground at the test site Please turn off the output before connecting/disconnecting the test object The voltage output of over 36V is considered as dangerous and care must be taken It’s not allowed to feed external voltage into the voltage/current output sockets...
  • Page 5: Designed Applications

    PW336i Hardware User Manual 3.Designed applications  PW336i can be used by power plants, 8 binary inputs for potential free or substations, and relay manufactures, etc, for potential contacts the following test applications. Binary outputs  4 binary outputs for potential free...
  • Page 6: Operation Preparation

    PW336i Hardware User Manual 4.Operation preparation 4.1 Preparation Be sure that the following preparation/system components are ready before operating the test equipment:  PW336i test equipment  Main supply cable (delivered)  LAN control cable (delivered)  PC with PowerTest software properly installed ...
  • Page 7: General Description

    PW336i Hardware User Manual 5.General description 5.1 Block diagram PW336i Universal Test System Diagram Power supply and control Power Supply VOLTAGE CONTROL 16 bit D/A Aux DC generator 0-300V DC, 100W Control Signal 6×30A for AR-10 Binary output 1-4 3x30A for AR-7D...
  • Page 8: Front Panel

    PW336i Hardware User Manual 5.3 Front panel Current Output 1 and 2 (A-C/a-c) Pause Button Voltage output A,B,C,Z Communication Interface of Computer (Ethernet) Binary input A-D LED Indication Auxiliary DC Output Earth socket 5.4 Ethernet port The Ethernet port is used to connect to external PC via Ethernet control cable.
  • Page 9: Pause Button

    PW336i Hardware User Manual 5.5 Pause Button The Pause button on the front panel is designed to cut the current/voltage outputs either for test purpose or under emergency case. ‘Manual’ control mode ‘Auto’ control mode Push ‘Pause’ button cut the current/voltage...
  • Page 10: Rear Panel

    PW336i Hardware User Manual 5.7 Rear Panel Connector for mains supply Binary Input E~H Power switcher Binary Output 1~4 IP reset GPS interface...
  • Page 11: Gps Interface

    PW336i Hardware User Manual 5.8 GPS Interface This interface is used to connect to our optional PGPS02 GPS-based synchronization device or IRIG-B based synchronization device. Signal Contact pin Power Ready DB9 Chassis contact, male ---------------------------------------------- Note: PPS means Pulse Per Second...
  • Page 12: Ip Reset

    PW336i Hardware User Manual 5.9 IP reset This reset button is used to restore the IP address of PW336I to the default factory setting.  Press this button  Switching on the power for PW336I After this operation the IP address will be restored to the following settings.
  • Page 13: Hardware Configuration

    PW336i Hardware User Manual 6.Hardware Configuration configuration 6.1 Current Generators  Basic QuickTest (4V,6I)  State sequence (4V, 6I) PW336I has 6 current generators in two Protection Differential(6I) groups. They can be configured as either 3 Advanced Advanced Differential(6I) currents mode or 6 current modes.
  • Page 14 PW336i Hardware User Manual 1-phase ac (3L-N) 1 × 0 … 90 A 1-phase ac (L-L) 1 × 0 … 30 A 6 × 0 … ±10A 1-phase dc (L-N) 1 × 0 … ±60 A 1-phase dc (3L-N) Power 3-phase ac (L-N) 3 ×...
  • Page 15: Current In Series Connection In 3 Current Mode

    PW336i Hardware User Manual 6.3 Current in Series Connection 6.4 Voltage Generators in 3 Current Mode PW336I has 4 voltage generators. In 3 current mode the two current generators can be connected in series to increase the compliance voltage. Example: IA and IB are connected in series 6.5 Connect two voltage...
  • Page 16: Binary Inputs And Outputs

    PW336i Hardware User Manual 7.Binary Inputs and Outputs 7.2 Binary Input 7.1 General Description The device has 8 binary inputs. Electricity is PW336I has 8 binary inputs in two groups. isolated in A-H. Space contact or active contact (15V-250V) can be set by software.
  • Page 17: Polarity Of Binary Inputs

    PW336i Hardware User Manual 7.3 Polarity of Binary Inputs 7.5 Isolation of the binary inputs The polarity reference of the binary inputs are shown All 8 binary inputs are gavanically isolated bellow. from each other. 7.4 Binary configuration The software interface for binary configuration (A-H) shows below.
  • Page 18: Binary Outputs

    PW336i Hardware User Manual 7.7 Binary outputs has 4 binary outputs. PW336I The binary outputs 1-4 are placed on the rear panel. These 4 binary outputs are potential free relay contact output.
  • Page 19: Getting Ready For Pc Controlled

    2~254 (except 133). Steps for setting IP address for computer. PowerTest test software must be properly installed on the PC to control PW336I. The Step 1: Left click ‘Start/Control panel/Network installation description of PowerTest test connection’...
  • Page 20 PW336i Hardware User Manual Step 2: Right click ‘Local connection’ icon Step 4: Click the ‘Properties’ button Step 3: Left click the ‘Properties’ ---------------------------------------------- Note: the last section of IP address can be any number between 2-254 (except 133) ---------------------------------------------- Step 5: Make the settings ...
  • Page 21 PW336i Hardware User Manual Step 7: Check if IP is set properly If IP address is properly set we will see on the right bottom corner the following display If we see the following display on the right bottom corner then we need to make the check as mentioned bellow ...
  • Page 22: Pw336I-Related Products And

    PW336i Hardware User Manual 9.PW336i-Related Products and Accessories This chapter describes the optional equipments and accessories for the PW336i test set. Please visit the PONOVO Web site www.relaytest.com / www.ponovo.com.cn for up-to-date information. Optional accessories Standard accessories Item Part No.
  • Page 23: Pgps02-Gps-Based Synchronization Device

    SAG0101 PGPS02 Via the PIRIG-B interface box users can You can synchronize two or more PONOVO connect devices to the PW336i test set that test sets by connecting a PGPS either transmit or receive the IRIG-B time synchronization unit to each of the test sets’...
  • Page 24: Pss01 Circuit Breaker Simulator

    PW336i Hardware User Manual 9.3 PSS01 Circuit Breaker 9.4 PACB108 Scanning Head Simulator The passive optical scanning head PACB108 detects the status of an LED, that is either an t can simulate circuit breaker behaviors in optical pulse output from an energy meter or...
  • Page 25: Standard Accessories

    1. Colour coded current cables SAW0201/ 0203 colour coded current cable 2xred, 2xblack, 2xyellow, 2xblue xred, 1xblack, 1xyellow, 1xblue Amount: The current cables to connect the PW336i output to other safety sockets of, generally the current parts, voltage and signal tripping.
  • Page 26 SAW0201 Colour coded voltage cable Amount: Amount: 1x red, 1x yellow, 1x white, 1x blue, 1x black The voltage cables to connect the PW336i output to other safety sockets of, generally the voltage parts, current and signal tripping. Signal Cable...
  • Page 27 PW336i Hardware User Manual Flexible Terminal Adapter SAW0206 Flexible terminal adapter Amount: 10xred, 10xblack Flexible terminal adapter connect to screw-clip terminals. -------------------------------------------------------------------------------------- Notes: One end of the adapters have no insulator, users should make sure there is no output during connecting the adapters. Users insert the non-safety into the terminals and screw it firmly, then connect the test lead with the other end.
  • Page 28 PW336i Hardware User Manual Jumper Cable SAW0207 Flexible jumpers Amount: 4xblack Flexible jumper connects current outputs in parallel. Crocodile Clips SAW0208 Crocodile clips Amount: 2xred, 2xblack, 2xyellow, 2xblue Crocodile clips for secondary side to connect to pins or screw types.
  • Page 29 PW336i Hardware User Manual U Clamps SAW0209 U clamps 1# SAW0210 U clamps 2# Amount: 10xred, 10xblack 5xred, 5xblack It is used to connect test leads with screw type terminals. ------------------------------------------------------------------------------------------ Notes: One end of the adapters have no insulator, users should make sure there is no output during connecting the adapters.
  • Page 30 PW336i Hardware User Manual Pin clamps SAW0211 Pin clamps Amount: 4xred, 4xblack It is used to connect test leads with screw type terminals. Banana plug adapter SAW0211 Banana plug adapter Amount: 3xred, 3xyellow, 3xblue, 3xblack Banana plug adapter for screws to connect regular test leads to UK terminals.
  • Page 31 D03 Power code QP3D Power code Amount: 1 piece Power cord connects the PW460 with power supply socket. PONOVO will provide relevant plug socket according to different countries. ------------------------------------------------------------------------------------------ NOTE: D03: Adapter is mainly used in German, Finland, France, Norway, Sweden, Poland, South Korean, Austria, Spain, Hungary, Czech, Ukraine, Turkey, Brazil and Russia etc.
  • Page 32 Amount: 1 piece Earthing lead connects the PW336i with ground to ensure kit safety. ------------------------------------------------------------------------------------------ Notes: In order to avoid static induction, users should connect the PW336i with ground reliably before testing. ------------------------------------------------------------------------------------------ 12. PC control cable (LAN) SAW0012 PC control cable (LAN) Amount: 1 piece The LAN cable connects the PW336i with PC for communications.
  • Page 33: Transportation Case

    PW336i Hardware User Manual 9.5.2 Transportation Case The large-size case with wheels is designed for heavy transport stress with folding hand it is made of fireproof materials and smooth rolling rubber tires. SAC0105 Transportation case Dimension: 465x250x525mm (WxHxD) Weight: 10Kg.
  • Page 34: Troubleshooting

    PW336i Hardware User Manual 10.Troubleshooting 1. Power Indicator doesn’t work. 1) Check if there is electricity in power supply. 2) Check if the input fuse is blown. If the fuse is broken, check if the input power is correct and change the fuse. There are two fuses in the box which is under the mains jack. One is for working, the other is for reserve.
  • Page 35 PW336i Hardware User Manual Sometiems computer system may affect online result, please change computers. Please note if the kit IP address has been changed. Press “IP reset” button to switch on kit and confirm the IP in “IP Set”. 4. The current and voltage output is not accurate.
  • Page 36 PW336i Hardware User Manual or voltage short-circuit alarm while high voltage output. 7. Output waveform is incorrect. Check the setting output value. Check if the open circuit casue no oscillogram. Check if the parameter setting of output monitor windows is correct, each amplitude is too big, and the phase color is the same as grounding.
  • Page 37 PW336i Hardware User Manual When the frequency is not accurate, check if the current and voltage’s output frequncy in general unit are correct first. If the frequency differential is beyond the range, please check as following method: 1) Check if the site instrument works well.
  • Page 38 PW336i Hardware User Manual 13. How to output a greater current than allowed max. single phase current? The three-phase current power of kit can be used by parallel connection. Users need set the phase output. It is suggested to set amplitude the same.

Table of Contents