SECO-LARM SLI Enforcer E-964-D390Q Manual

SECO-LARM SLI Enforcer E-964-D390Q Manual

Twin photobeam detectors
Hide thumbs Also See for SLI Enforcer E-964-D390Q:

Advertisement

Twin Photobeam Detectors
Model #
E-964-D390Q*
E-960-D290Q
E-960-D190Q
E-960-D90Q
* Multi-frequency version
Manual
Outdoor Range
390 ft (120m)
290 ft (90m)
190 ft (60m)
90 ft (30m)
®
Indoor Range
790 ft (240m)
590 ft (180m)
390 ft (120m)
190 ft (60m)

Advertisement

Table of Contents
loading

Summary of Contents for SECO-LARM SLI Enforcer E-964-D390Q

  • Page 1 Twin Photobeam Detectors Manual Model # Outdoor Range Indoor Range E-964-D390Q* 390 ft (120m) 790 ft (240m) E-960-D290Q 290 ft (90m) 590 ft (180m) E-960-D190Q 190 ft (60m) 390 ft (120m) E-960-D90Q 90 ft (30m) 190 ft (60m) * Multi-frequency version ®...
  • Page 2: Table Of Contents

    Pole mounting brackets (2 sets) Transmitter x 1 Receiver x 1 Mounting plates x 2 IMPORTANT – Do not connect to power until the sensor is completely installed and the installation has been double-checked. SECO-LARM U.S.A., Inc.
  • Page 3: Choosing A Location

     Do not mount where animals could break the beams. Fig. 2: Vertical and Horizontal Adjustments Fig. 3: Typical Installations Vertical Side Views Vertical adjustment adjustment screw 32" ±5° 39" (10°) Top Views Horizontal adjustment ±90° (180°) SECO-LARM U.S.A., Inc.
  • Page 4: Typical Installation

    Then reattach the plate, connect the wires, and snap on the sensor unit to the mounting plate, connect the cover. See fig. 6. wires, and snap on the cover. See fig. 5. SECO-LARM U.S.A., Inc.
  • Page 5: Wiring The Transmitter - Pole Mount

    Tamper output Power Tamper output Power Alarm output N.C. switch 120V (AC/DC) 1A 10~ 30 VAC/VDC N.C. switch 120V (AC/DC) 1A 10~ 30 VAC/VDC 120V (AC/DC) 1A (Triggers if cover detached) (non-polarized) (Triggers if cover detached) (non-polarized) SECO-LARM U.S.A., Inc.
  • Page 6: Examples Of Ways To Connect Sensors

    ○ ○ ○ ○ ○ ○ ○ ○ ○ Transmitter Receiver Transmitter Receiver Control panel (12VDC) Example connection 4 – Two stacked Power Alarm signal ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ SECO-LARM U.S.A., Inc.
  • Page 7: Selectable 4-Channel Beam Frequency

    Switch position Multiple Sensor Sample Application (For E-964-D390Q model only): 1. Single pair multiple layer application. Sensor #1 Sensor #2 Sensor #3 Sensor #4 2. Long distance series application. Sensor #1 Sensor #2 Sensor #3 Sensor #4 SECO-LARM U.S.A., Inc.
  • Page 8 ENFORCER Twin Photobeam Detectors 3. Two layer (double stacked) applications. Sensor #1 Sensor #2 Sensor #3 Sensor #4 Sensor #5 Sensor #6 4. Perimeter security application. 5. Two layer (double stacked) perimeter security application. SECO-LARM U.S.A., Inc.
  • Page 9: Adjusting The Alignment

    Adjust the vertical angle by turning the vertical 1.1~1.6 V 1.1~1.7 V Fair adjustment screw until the VOM indicates the highest <1.0V <1.0V Re-adjust voltage. Note: 4VDC is maximum possible reading. NOTE – Do not interrupt the beam while adjusting alignment. SECO-LARM U.S.A., Inc.
  • Page 10: Adjusting The Response Time

    Power LED (Tx & Rx) Green LED ON: Indicates connected to power Laser wavelength 650nm Laser output power ≤5mW Alignment angle Horizontal: ±90°, Vertical: ±5° Operating temperature -13°~131° F (-25°~55° C) Weight 2.5-lb (1.1kg) Case PC Resin *Factory default is 50ms SECO-LARM U.S.A., Inc.
  • Page 11: Dimensions

    Lenses out of alignment. erratic in bad weather. If still erratic, realign the lenses. a. Reduce the response time. Frequent false triggers from a. Too sensitive. b. Change the transmitter and/or leaves, birds, etc. b. Bad location. location. SECO-LARM U.S.A., Inc.
  • Page 12 WARRANTY: This SECO-LARM product is warranted against defects in material and workmanship while used in normal service for one (1) year from the date of sale to the original customer. SECO-LARM’s obligation is limited to the repair or replacement of any defective part if the unit is returned, transportation prepaid, to SECO-LARM. This Warranty is void if...

Table of Contents