Adjusting The Response Time; Testing The Unit; Specifications - SECO-LARM SLI Enforcer E-964-D390Q Manual

Twin photobeam detectors
Hide thumbs Also See for SLI Enforcer E-964-D390Q:
Table of Contents

Advertisement

ENFORCER Twin Photobeam Detectors
Adjusting the Response Time: (IMPORTANT)
1. The response time adjustment knob sets how long the beam can be
interrupted before triggering the alarm (see fig. 11):
a. A short response time (high sensitivity) is suitable for catching fast
moving intruders, but more susceptible to false alarms.
b. A long response time (low sensitivity) reduces false alarms, but fast
moving intruders may not trigger the sensor.
2. Adjust the knob to the site's situation. You may need to make adjustments
later after the walk-through test.
IMPORTANT: Note that the response time is set at the factory to the shortest time (50ms).
After installation is complete please adjust to best suit the site situation.

Testing the Unit:

1. Power up the transmitter and receiver.
2. If the yellow or red LED remains steady ON even
when the beam is not interrupted, re-adjust the
alignment.
3. Walk between the transmitter and receiver to
interrupt the beams. Walk at various speeds, and
adjust the response time as needed.
Table 5: Specifications
Model
Max. range (outdoor)
Max. range (indoor)
Max. current (Tx & Rx)
No. of beam channel
Voltage output (+/-10%)
Power
Detection method
Response time*
Alarm output
Tamper output (Tx & Rx)
Alarm LED (receiver)
Signal LED (receiver)
Power LED (Tx & Rx)
Laser wavelength
Laser output power
Alignment angle
Operating temperature
Weight
Case
*Factory default is 50ms
10
E-960-D90Q
E-960-D190Q
90' (30m)
190' (60m)
390' (120m)
64mA
N/A
1~4 V
10~30 VAC/VDC (non-polarized)
Simultaneous breaking of 2 beams
50~700 ms (variable)
NO/NC relay, 1A@120VAC, minimum 1 sec.
N.C. switch, 1A@120VAC
Red LED - ON: When transmitter and receiver are not aligned or when
beam is broken.
Yellow LED - ON: When receiver's signal is weak or when beam is
broken.
Green LED ON: Indicates connected to power
650nm
≤5mW
Horizontal: ±90°, Vertical: ±5°
-13°~131° F (-25°~55° C)
2.5-lb (1.1kg)
PC Resin
NOTE – The alarm will be triggered
only if both the upper and lower
beams are simultaneously interrupted.
IMPORTANT –Test the detector
periodically to ensure the alignment
and delay time settings are suitable
for the site.
E-960-D290Q
190' (60m)
290' (90m)
590' (180m)
70mA
N/A
SECO-LARM U.S.A., Inc.
Fig. 11:
Adjusting the
Response Time
300ms
 
50ms
E-964-D390Q
390' (120m)
790' (240m)
74mA
88mA
N/A
700ms
4

Hide quick links:

Advertisement

Table of Contents
loading