ENFORCER Twin Photobeam Detectors

Typical Installation:

The photoelectric beam lens can be adjusted horizontally ±90°, and vertically ±5° (see fig. 2).
This allows much flexibility in terms of how the transmitter and receiver can be mounted.
See fig. 3.
Install at a distance of 32" to 39" (80 to 100 cm) above the ground for most situations. See fig. 3.

Running the Cable:

Run a cable from the alarm control panel to the photobeam sensor. If burying the cable is
required, make sure to use electrical conduit. Shielded cable is strongly suggested. See Table 1
for maximum cable length.
Table 1: Cable Length
Model
E-960-D90Q
Wire Size
12V
AWG22
320m
0.33mm
2
1,050ft
0.0005in
2
AWG20
550m
0.52mm
2
1,800ft
0.0008in
2
AWG18
800m
0.83mm
2
2,600ft
0.0013in
2
AWG17
980m
1.03mm
2
3,190ft
0.0016in
2
Note (1): Max. cable length when two or more sets are connected is the value shown in
Table 1 divided by the number of sets.
Note (2): The power line can be wired to a distance of up to 3,300ft (1,000m) with AWG22
(0.33mm
Wiring the Transmitter – Wall Mount:
1. Remove the cover. Remove the screw under
the lens unit in order to detach the mounting
plate. See fig. 4.
2. If the sensor wiring comes from inside the
wall – Break a hole in the mounting plate's
rubber grommet, and pull the cable through
the grommet's hole. Then run the cable
through the hole near the top of the sensor
unit so it comes out the front. Using two of the
included mounting screws, attach the
mounting plate to the wall. Then reattach the
sensor unit to the mounting plate, connect the
wires, and snap on the cover. See fig. 5.
4
E-960-D190Q
24V
12V
2,800m
280m
18,000ft
920ft
4,800m
450m
15,750ft
1,480ft
7,200m
700m
23,620ft
2,300ft
8,800m
850m
28,870ft
2,790ft
) telephone wire.
2
E-960-D290Q
24V
12V
2,400m
200m
7,870ft
660ft
4,200m
350m
13,780ft
1,150ft
6,200m
500m
20,340ft
1,640ft
7,600m
590m
24,930ft
1,940ft
3. If the sensor wiring is run along the surface
of the wall – There are two plastic
knockouts on the back of the sensor unit,
one on top and one on bottom. Break out
the appropriate knockout, and pull the
wiring through the knockout. Then run the
wiring through the hole near the top of the
sensor unit so it comes out the front. Using
two of the included mounting screws, attach
the mounting plate to the wall. Then
reattach the sensor unit to the mounting
plate, connect the wires, and snap on the
cover. See fig. 6.
E-964-D390Q
24V
12V
1,600m
110m
5,250ft
390ft
3,000m
170m
9,840ft
560ft
4,200m
250m
13,780ft
820ft
5,200m
310m
17,060ft
1,020ft
SECO-LARM U.S.A., Inc.
24V
900m
2,950ft
1,400m
4,590ft
2,200m
7,220ft
2,600m
8,530ft

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents