Wiring the Transmitter – Pole Mount:
(NOTE – Pole mounting bracket required.)
1. Remove the cover. Remove the screw under
the lens unit in order to detach the mounting
plate. See fig. 4.
2. Break a hole in the mounting plate's rubber
grommet, and pull the cable through the
grommet's hole. Then run the cable through
the hole near the top of the sensor unit so it
comes out the front. Use the included
mounting bracket to mount to the pole. Then
reattach the sensor unit to the mounting
Fig. 4: Remove the Transmitter Cover
Fig. 6: Wall Mount, Wire Runs along Wall
Fig. 8: Wiring
Transmitter
1
2
10~30
AC/DC
Power
10~ 30 VAC/VDC
(non-polarized)
SECO-LARM U.S.A., Inc.
- or -
6
7
N.C.
Tamper output
N.C. switch 120V (AC/DC) 1A
(Triggers if cover detached)
ENFORCER Twin Photobeam Detectors
plate, connect the wires, and snap on the
cover. See fig. 7.
Wiring (fig. 8)
1. Screw the wires tightly to avoid slipping off
the terminals, but not so tight that they
break.
2. Screws on terminals which are not used
should be tightened.
3. Grounding may be necessary, depending on
the location.
Fig. 5: Wall Mount, Wire from Inside Wall
Fig. 7: Pole Mount
Receiver
1
2
3
10~30
COM.
AC/DC
Power
Alarm output
10~ 30 VAC/VDC
120V (AC/DC) 1A
(non-polarized)
4
5
6
7
N.C.
N.C.
N.O.
Tamper output
N.C. switch 120V (AC/DC) 1A
(Triggers if cover detached)